Moeller Marine XControl PLC System AWB2700-1428GB User Manual

Page of 54
Functions of the Operator 
Module
12/01 AWB2700-1428GB
40
Shutting down the system 
X
Use the MSS to choose MAIN MENU SYSTEM SHUTDOWN 
and press the MSS.
The cursor is positioned on the ENTER menu item.
X
Press the MSS to execute the function. 
The STOP LED will go out. The display shows:
/ is a symbol. It keeps turning as long as the function is in progress. 
Once the function has been completed the following message will 
appear:
X
Switch off the power supply.
Switching off the power supply
Switching off the power supply of the UPS device will cause the 
Power Supply contact to open. The contact will break the PFI loop 
on the XC600 controller, which causes the system to shutdown. 
Depending on the operating status, the RUN or STOP LED will go 
out.
The display shows:
/ is a symbol. It keeps turning as long as the function is in progress. 
The UPS device will switch off the power supply after two minutes.
SHUT DOWN
IN PROGRESS
/
TURN OFF
YOUR
CONTROLLER
PFI SHUTDOWN
IN PROGRESS
/