BENDIX TCH-001-048 Data Sheet

Page of 1
© 2002 Bendix Commercial Vehicle Systems LLC.  Printed in U.S.A.     All rights reserved.
Technical 
Bulletin
Bulletin No: TCH-001-048
Effective Date:   8/1/02
Cancels:  NA
Page: 1 of 1
Subject:
DuraFlo-596 Compressor Requirements
The Bendix Duraflo-596 Compressor has two features that we recommend
be considered carefully when maintenance is performed.  The DF-596 is
designed to be naturally aspirated, unlike many compressors that use turbo-
supplied air.  Also, the DF-596 uses an Energy Saving System (ESS)
unloader that requires a D-2 governor and an SV-1 synchro valve for
correct operation.  Improperly configured systems may result in damage to
the compressor unloader.  Damages caused by incorrect installation or non-
naturally aspirated applications are not covered under the warranty policy.
For ease of maintenance, Bendix provides a module for compressor-mount or
remote-mount applications with the special D-2 governor and SV-1 that the
DuraFlo-596 requires.  If making individual repairs to the D-2 or SV-1, use
only genuine Bendix parts.
Replacement Parts
Piece Number
Description
  5007404
D-2/SV-1 module with braided hoses for compressor-mount or remote-mount locations.
  5007116
D-2/SV-1 module with plastic hoses for remote-mount locations.
    109662
D-2 (Non-standard governor used for DF-596. 110 psi to 130 psi pressure range.)
  5005365
SV-1 (high durability model is used for this application.)
Figure 1: DuraFlo-596
For more information refer to Service Data Sheet SD-01-670 (BW1845).
Figure 2: Typical D-2/SV-1 module installation.