Maretron LLP FFM100 User Manual

Page of 28
 
 
 
 
 
Revision 1.2 
 
Page 19 
®
®
6  Technical Specifications 
Specifications 
Parameter 
Value 
Comment 
Accuracy (Differential Mode) 
±1.75% of 
reading 
Using M1RSP-2R-E8 sensors 
K factors programmed into FFM100 
4:1 fuel supply/fuel consumption ratio 
Accuracy (Two Independent 
Sensors) 
±0.25% of 
reading 
Using M1RSP-2R-E8 sensor 
K factors programmed into FFM100 
Resolution 0.1 
LPH 
(0.026 GPH) 
 
 
Certifications 
Parameter 
Comment 
NMEA 2000
®
 Level 
Maritime Navigation and Radiocommunication Equipment & Systems 
IEC 61162-3 
Maritime Navigation and Radiocommunication Equipment & Systems 
Tested to IEC 60945 
FCC and CE Mark 
Electromagnetic Compatibility 
 
NMEA 2000
®
 Parameter Group Numbers (PGNs) - See Appendix A for Details 
Description 
PGN # 
PGN Name 
Default Rate 
Periodic Data PGNs 
127489  Engine Parameters, Dynamic 
2 Times/Second 
127497  Trip Parameters, Engine 
1 Time/Second 
130312 Temperature 
0.5 
Times/Second 
Response to Requested PGNs 
126464  PGN List (Transmit and Receive) 
N/A 
126996 Product 
Information 
N/A 
126998 Configuration 
Information 
N/A 
Protocol PGNs 
059392  ISO Acknowledge 
N/A 
059904 ISO 
Request 
N/A 
060928 ISO 
Address 
Claim 
N/A 
065240 ISO 
Address 
Command 
N/A 
126208 NMEA 
N/A 
Maretron Proprietary PGNs 
128720  Configuration 
N/A 
 
Electrical 
Parameter 
Value 
Comment 
Operating Voltage 
9 to 32 Volts 
DC Voltage 
Power Consumption 
150mA 
Maximum Current Drain 
Load Equivalence Number (LEN) 
NMEA 2000
®
 Spec. (1LEN = 50mA) 
Reverse Battery Protection 
Yes 
Indefinitely 
Load Dump Protection 
Yes 
Energy Rated per SAE J1113 
 
Mechanical 
Parameter 
Value 
Comment 
Size 
3.50” x 4.20” x 2.03” 
(88.9mm x 106.7mm x 51.6mm) 
Including Flanges for Mounting 
Weight 
13 oz. (368.5 g)