Maha Energy MH-C9000 User Manual

Page of 4
PRINTED IN TAIWAN A03-3713420-496 
MODES OF OPERATION 
 
This section explains various modes and when to use them. To enable 
each mode, refer to the “Operation” section. 
 
 
Charge Mode  
 
• 
Recharges the battery at the selected rate.  
• 
Useful when battery needs to be recharged without determining the 
capacity of the battery. It should be used on batteries known to be in 
good condition and have been in continuous use.  
• 
Requires the least amount of time.  
 
Refresh & Analyze Mode  
 
• 
First recharges the battery, rest for one hour, discharge, rest, then 
recharges again. Charging and discharging rates are programmable.  
• 
Reports the discharge capacity at the end of the cycle.  
• 
Useful when the battery capacity needs to be determined. Also 
useful for battery with degraded performance.  
• 
Recommended once every ten cycles for NiMH batteries.  
 
Break-In Mode (IEC capacity analysis)  
 
• 
Applies a 16-hour 0.1C charge (0.1 times the capacity of the 
battery), rest of one hour, followed by a 0.2C discharge, rest again, 
and finally a 16-hour 0.1C recharge again.  
• 
Recommended for brand-new batteries. This process is also known 
as “Forming Charge.” Also recommended with batteries that cannot 
be rescued by the Refresh & Analyze mode.  
• 
Recommended once every 30 cycles for NiMH batteries.  
• 
Requires 39 to 45 hours to complete.  
• 
The process follows the IEC standard for determining battery 
capacity. 
 
Discharge Mode 
 
• 
Discharges the battery at the selected rate.  
• 
Useful for analyzing the amount of charge stored in the battery. 
Battery not recharged at the end of the cycle.  
 
Cycle Mode 
 
• 
Performs a charge-discharge cycle for the programmable number of 
times. Charging and discharging rates are also selectable. At the 
end of the cycle, a final recharge is applied.  
• 
Suitable for cycling the batteries multiple times. 
 
The following table summarized the recommended mode for typical 
battery conditions:  
 
Battery Condition 
Mode 
 
Brand-new batteries 
 
Break-In 
 
NiMH batteries that have been used 
frequently (at least once every two weeks) 
 
Charge  
 
Batteries in storage for more than two 
weeks but less than 3 month 
 
Refresh & Analyze  
 
Batteries in storage for more than 3 month 
 
Break-In 
 
Batteries showing poor performance 
Refresh & Analyze for 
one to three times. 
 
 
 
Battery Rescue Steps  
 
For batteries that do not perform favorably after using the mode 
recommended above, the following sequence can be applied.  
 
1. 
Refresh & Analyze for one to three times.  
2. 
If capacity is still low, use Break-In mode.  
3. 
If the step 1 to step 2 shows some capacity improvement (> 10%), 
repeat Break-In mode for one to three times. If no significant 
improvement, battery probably at end of useful life.  
 
 
OPERATIONS  
 
 
1. 
Connect the power adapter DC connector to the charger.  
 
Then, plug the power adapter into a compatible outlet (100-240VAC, 
50/60Hz). 
 
TIP: When operating the charger outside of its intended region of 
use, simply use a plug-changer (Maha part number MHS-TC400 
worldwide plug-changer kit). Transformer is not necessary. 
 
2. 
Raise the lift rod located on the backside of the charger.  
 
3. 
Insert AA or AAA battery.  
 
 
 
Inserting AA batteries 
 
Inserting AAA batteries 
 
 
TIP: If charging two batteries, inserting them in the first and fourth 
slot offers better cooling and lowers battery temperature. 
 
 
4. 
When a new battery is detected, the LCD will display an arrow below 
the bank number and prompt for the mode by flashing “MODE”.  
 
 
 
 
Use the UP and DOWN arrow keys to choose the desired mode. 
Press ENTER to make the selection.  
 
If no key is pressed within five seconds, the charger will proceed to 
the default mode which is charging with 1000mA rate. 
 
 
NOTE: the default mode may not be suitable for battery lower than 
500mAh and higher than 1500mAh. See “General Battery 
Education” for more details.  
 
If more than one battery is inserted at a time (without key press), the 
charger will prompt for programming in the order in which the 
batteries were inserted.  
 
 
5. 
If CHARGE mode is selected: 
 
The charger will prompt for the charging rate by flashing “SET CHG 
RATE
.” Use the UP and DOWN key to choose the desired current. 
Press ENTER to make the selection. Refer to the “General Battery 
Education” section on choosing an appropriate rate.