Lucent Technologies MN10285K User Manual

Page of 338
Timers
16-Bit Timer Setup Examples
Panasonic  Semiconductor  Development  Company
MN102H75K/F75K/85K/F85K LSI User Manual
122
Panasonic
To service the interrupts:
Run the interrupt service routine. The routine must determine the interrupt group, 
then clear the interrupt request flag.
Either the TM5IA or TM5IB signal can control the timer 5 count direction. The 
count direction is determined at the opposite edge from the count edge (at the 
source clock transition occurring in the middle of the count cycle.).
Timer 5 does not operate in STOP mode, when B
OSC
 is off. If you use an external 
clock, it must be synchronized to B
OSC
.
Figure 4-51 shows an example timing chart. In this example, an interrupt occurs 
when the timer switches from down to up counting.
Figure 4-51 External Count Direction Control Timing (Timer 5)
TM5CA
TM5CB
TM5BC
TM5IA
Interrupt
0000
1FFF
1FFF
1001
1000
0FFF
0002
0001
0000
1FFE
1FFE
1FFD
1FFF
1000
B
B
OSC
/4