Lucent Technologies Speaker 585-210-940 User Manual

Page of 106
 
 
Introduction to Disk Mirroring 
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
How CMS implements disk mirroring
8
Mirror layout on a 
Sun 
Enterprise 3500 
computer
1
On a 
Sun Enterprise 3500 platform, the mirror layout must always be 
based upon the bays in which the disks are installed. Submirrors 11, 15, 
and 19 are the disks in the lower bay (targets 0 through 3 on controller 0); 
submirrors 12,16, and 20 are the disks in the upper bay (targets 4 
through 7 on controller 1). The table below shows the mirror layout.
Required hardware
1
In order for your CMS system to be mirrored, it must have the following 
hardware installed in addition to the hardware already installed:
For a 
Sun Enterprise 3500 system, two GigaByte Interface 
Converter (GBIC) modules. One will be installed into the UA slot on 
the FC-AL Interface board, and the other will be installed into GBIC 
Port 1 on the Sbus I/O board (see the illustration on page 15).
For a 
Sun Enterprise 3500 system, a fiber cable to connect the UA 
port GBIC to GBIC Port 1 on the I/O board.
Twice the number of disk drives needed for an unmirrored system. 
All the disks must be the same size.
mirror d13
(root) filesystem
mirror d21
/cms filesystem
mirror d17
swap partition
(CMS r3v8)
No. 
Disks
submirror
d11
submirror
d12
submirror
d19
submirror
d20
submirror
d15
submirror
d16
2
c0t0d0s0
c1t4d0s0
c0t0d0s3
c1t4d0s3
c0t0d0s4
c1t4d0s4
4
c0t0d0s0
c1t4d0s0
c0t0d0s3
c0t1d0s1
c1t4d0s3
c1t5d0s1
c0t0d0s4
c1t4d0s4
6
c0t0d0s0
c1t4d0s0
c0t0d0s3
c0t1d0s1
c0t2d0s1
c1t4d0s3
c1t5d0s1
c1t6d0s1
c0t0d0s4
c1t4d0s4
8
c0t0d0s0
c1t4d0s0
c0t0d0s3
c0t1d0s1
c0t2d0s1
c0t3d0s1
c1t4d0s3
c1t5d0s1
c1t6d0s1
c1t7d0s1
c0t0d0s4
c1t4d0s4