Thermador VTR1030P Installation Instruction

Page of 19
English 3
Step 3: INSTALLATION
1. Hold the blower on the wall. 
Note the direction of the air conduction.
2. Mark the 4 mounting boreholes.
At least one screw must be installed through a 
stud.
All hardware must be suitable for the wall’s 
construction materials.
3. Drill the 4 x ¼'' (6.35 mm) Ø mounting boreholes.
Insert wall anchors and screw the blower to the wall.
4. Connect the ducting from the blower to the extractor 
hood and feed to the outside.
5. Connect the blower to the extractor hood with an 
extension cable, if required.
Use the added connector to hard-wire to the blower, if 
required.
Use the wire diagram for connecting.
NOTE: Confirm that the blower is securely attached to the 
wall and all connections are secure.
WARNING
The additional cover on the plug must always be 
attached and closed for safety reasons.
Not needed wires must be isolated, capped with wire 
nuts and stored in a safe position.