Lynx L36R1LP Installation Instruction

Page of 42
Safety Practices & Precautions
5
24. Do not use the grill until a leak check has been performed (see page 6).
25. Do not move grill while in use or hot.
26. Never place more than 30 pounds on a side shelf. Do not lean on shelves.
27. Do not operate grill under the influence of alcohol or drugs.
28. If any burner does not light or goes out during operation, turn off all gas control
knobs with hood open and wait five (5) minutes before attempting to re-light.
LOCATION:
Never connect any unregulated gas supply to the grill.
The regulator with hose Type 1 connection has the fol-
lowing safety features:
Œ
The system will not allow gas to flow until a posi-
tive connection has been made.
Œ
The system has a thermal element that will shut-
off the flow of gas between 115 and 150ºC (240
and 300ºF). 
Œ
The system has a flow limiting device which, when
activated, will restrict the flow of gas to 10 cubic feet per
hour.
NOTE:The cylinder control valve must be turned off before any connec-
tion is made or removed. NEVER USE GRILL WITHOUT LEAK TEST
ING THIS CONNECTION. 
Should the large black thermally sensitive coupling nut be exposed to temperatures above 115-150ºC it will 
soften and allow the regulator probe to disengage from the cylinder valve, thereby shutting off the flow of 
gas.  Should this occur, do not attempt to reconnect the nut.  Remove the entire regulator assembly and 
replace it with a new one.  The cause of the excessive heat should be determined and corrected before 
operating your grill again. The regulator probe also contains a flow-sensing element, which will limit the 
flow of gas to the regulator to a manageable amount (10 cubic feet/hour) in the event of a hose or regula
tor rupture.  If it is evident that the flow control device has activated the cause of the excess flow should be 
determined and correct ed before using your grill again. 
NOTE: Improper lighting procedures can cause the flow control to activate, resulting in reduced heat out
put. If this is suspected, to reset flow control, shut off all burner controls and cylinder valve, wait 30 sec
onds, then turn cylinder valve on extremely slowly wait five (5) seconds and turn burner valve on and light.
Rev. 04/2005