Dacor EG366SCHNGH Technical Manual

Page of 1
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.10
EG/ESG Series Slide-in Cooktop  
with ERV/PRV Series Slim Raised Vent
COMBINATION INSTALLATIONS
CAbINEt/CoUNtErtoP CUtoUt DImENsIoNs wIth rAIsED VENt - toP VIEw
CAbINEt/CoUNtErtoP CUtoUt DImENsIoNs 
wIth rAIsED VENt - sIDE VIEw
Document # PGCI-001
Revised 06/22/09   Page 1/1
Model 
No.
B - Cutout 
Width
D - Hole 
Offset
E - Raised 
Vent Cutout
EG366 
ESG366
36”  
(914 mm)
16 5/8” 
(422 mm)
33 1/2”  
(851 mm)
EG486 
ESG486
48”  
(1219 mm)
20 13/16” 
(529 mm)
43 1/2”  
(1105 mm)
Model 
No.
Approved Raised
Vent Models
EG366 
ESG366
ERV36, PRV36
EG486 
ESG486
ERV48, PRV48
Cutout tolerances: +1/16”, -0,  (+1.6 mm, -0) 
unless otherwise stated
Non combustible rear 
wall recommended
10” (254 mm) Min. to 
combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
3/8” (10 mm) Min. 
countertop overhang
2 5/8”
(67 mm)
Hole 1/2” dia. (13 mm), 
2 places, through platform
for hold down bolts 
1/2” (13 mm) 
countertop 
overhang
1” thick mounting platform Min.
Open to below to allow for raised 
vent, gas and electrical connections
Countertop
Countertop
1/2” (13 mm) 
countertop 
overhang
2” (51 mm)
1” (25 mm)
11 7/16” 
(291 mm)
15”
(381 mm)
24 5/8”
(625 mm)
CL
D
D
E
B
CL
CL
CL
Stiffener
Cabinet face
Control panel
Countertop
Dacor approved
raised vent
IMPORTANT: See raised vent
installation instructions for 
duct system layout/planning 
EG366 or EG486 cooktop
3/8” Min. (10 mm)
space behind
raised vent 
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Minimum
countertop 
height: 
30 1/4"
(768 mm)
EG or ESG 
series cooktop
IMPORTANT: Use only approved raised vent models