Revised 02/13/12   Page 1/2
ProDUCT DImENsIoNs - DECT365
21” (53.3 cm)
36” (91.4 cm)
34” (86.3 cm)
2”
(5.18 cm)
19-3/16” (48.8 cm)
19 3/16” (48.8 cm)
21” (53.3 cm)
30” (76.2 cm)
28 5/8” (72.7 cm)
2”
(5.18 cm)
ProDUCT DImENsIoNs - DECT304
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
NOTES:
1.  The cooktop is supplied with a flexible, 48 inch long 
power conduit consisting of two (2) insulated hot lead 
conductors (L1 and L2) and one (1) insulated ground 
conductor. There is no neutral connection. All leads are 
copper. The conduit is connected to the right rear corner 
of the cooktop. Do not cut or lengthen the conduit.
2.  These cooktops are not approved for recessed 
installation.
Model No.
Electrical Circuit Required
Total Connected 
Load*
Minimum Supply Wire Size 
Line and Ground Connections
DECT304
240 Vac, 60 Hz, 30 Amps.
6.7 kW (28 Amps.)
No. 10 AWG
DECT365
240 Vac, 60 Hz, 40 Amps.
9.4 kW (39 Amps.)
No. 8 AWG
* For reference only, See the product data label on bottom of unit for exact specifications.
 ELECTrICAL sUPPLy rEqUIrEmENTs
 WARNiNG
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information. 
•  This appliance must be installed in accordance with the 
accompanying installation instructions.
iMPORTANT: DECT series cooktops are not approved for installation with a raised vent.