Lynx L1600SLP Use & Care Manual

Page of 40
38   
 
|
 
 
SEDONA CARE & USE/INSTALLATION
Btu outPutS & MaXiMuM runS
mODEL-SPECIfIC bTU OUTPUTS
model 
tuBe Burner 
rotIsserIe 
Prosear™
total InPut
L400PS
1 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
46,000 Btu/Hr
L400PSR
1 @ 23,000 Btu/Hr
1 @ 12,500 Btu/Hr
1 @ 23,000 Btu/Hr
58,500 Btu/Hr
L500PS
1 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
46,000 Btu/Hr
L500PSR
1 @ 23,000 Btu/Hr
1 @ 12,500 Btu/Hr
1 @ 23,000 Btu/Hr
58,500 Btu/Hr
L600PS
2 @ 23,000 Btu/Hr
N/A
1 @ 23,000 Btu/Hr
69,000 Btu/Hr
L600PSR
2 @ 23,000 Btu/Hr
1 @ 14,000 Btu/Hr
1 @ 23,000 Btu/Hr
83,000 Btu/Hr
maxImum runs for all  
aPPlIanCes on suPPly lIne
Run Length
3/4” Pipe (in feet)
Max BTU for all  
Appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135.000
70
123,000
80
115,000