Wolf CG365TSLP Installation Guide

Page of 20
4   
|
   Wolf Customer Care 800.222.7820
SPECIFICATIONS
Gas Supply
Installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code.
Locate the gas supply as shown in the illustrations on 
pages 5–6.
The cooktop is equipped for use with natural or liquid 
propane (LP) gas. It is design certified by the Canadian 
Standards Association (CSA) for natural or LP gases. The 
product rating plate has information on the type of gas that 
should be used. For rating plate location, refer to the illustra-
tion below. If this information does not agree with the type 
of gas available, check with the local gas supplier. The gas 
pressure regulator is built into the unit.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure
5"
 (12.5 mb)
 WC
Min Line Pressure
7"
 (17.5 mb)
 WC
Max Pressure to Regulator
14"
 (34.9 mb)
 WC, .5 psi 
(3.5 kPa)
LP GAS
Gas Supply Pressure
10"
 (25 mb)
 WC
Min Line Pressure
11"
 (27.4 mb)
 WC
Max Pressure to Regulator
14"
 (34.9 mb)
 WC, .5 psi
 (3.5 kPa)
The cooktop must be connected to a regulated gas supply. 
The supply line must be equipped with an approved external 
gas shut-off valve located near the cooktop in an accessible 
location. Do not block access to the shut-off valve. Refer to 
the illustration below.
A gas supply line of 
3
/
4
"
 (19)
 rigid pipe must be provided to 
the cooktop. If local codes permit, a certified, 3'
 (.9 m)
 long, 
1
/
2
"
 (13)
 or 
3
/
4
"
 (19)
 ID flexible metal appliance connector is 
recommended to connect the units 
1
/
2
" NPT male inlet to 
the gas supply line. Pipe joint compounds, suitable for use 
with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected 
from the gas supply piping system during any pressure 
testing of the system at test pressures in excess of .5 psi
 
(3.5 kPa)
. The appliance must be isolated from the gas 
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test 
pressures equal to or less than .5 psi
 (3.5 kPa)
.
Wolf natural gas cooktops will function up to 10,250'
 
(3124 m)
 in altitude without adjustment and LP gas cooktops 
will function up to 8,600'
 (2621 m)
. If the installation exceeds 
these elevations, contact your authorized Wolf dealer for a 
high altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLY
TO APPLIANCE
 
Gas shut-off valve.
 
 
Rating plate location.
 
RATING PLATE