Viking VGCC5364GBKLP Installation Instruction

Page of 12
42” min.
 
(106.7 cm)
13” max.
 
(
33.0 cm)
6” min.
(15.2 cm)
18” min.
(45.7 cm
)
3/8”
 
(0.95 cm)
36” 
(91.4 cm)
29-7/8”
(75.9 cm)
A
(opening width)
Clearance Dimensions 
(Wood/Composite Overlay)
11
Clearance Dimensions 
(Proximity to Cabinets)
10
• This range may be installed directly
adjacent to existing 36” (91.4 cm) high
base cabinets.
IMPORTANT: The side trim MUST be 
3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using 
the adjustment spindles on the legs.
• The range CANNOT be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above 36”
(91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36” (91.4 cm) counter height.
• Within the 6” (15.2 cm) side
clearance to combustible vertical
surfaces above 36” (91.4 cm), the
maximum wall cabinet depth
must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm)
side clearance must be 18” 
(45.7 cm) above the 36” 
(91.4 cm) high countertop.
• Wall cabinets above the range must be a
minimum of 42” (106.7 cm) above the
range cooking surface for the full width 
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result  in  the  bottom  of  the  hood  being
66” (167.6 cm) to 72” (182.9 cm) above the
floor. Refer to the range hood installation
instructions  for  additional  information.
These  dimensions  provide  for  safe  and
efficient operation of the hood.
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
30”
(76.2 cm)
6”
(15
.2 c
m)
Wood/Composite 
Overlay
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
24”
(61.0 cm)
or
27”
(38.6 cm)
Wood/Composite 
Overlay
0”
 
(
0 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
Wall Installation
Island Installation
Note: Minimum clearance for back wall
is 0” with backguard or high-shelf. See
Standoff Bracket Removal section to
allow 0” clearance.
CAUTION
Burn hazard
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If a cabinet
storage is to be provided the risk can be
reduced by installing a rangehood that
projects horizontally a minimum 5” 
(12.7 cm) beyond the bottom of cabinets.
Range
Width
“A”
Dimension
30”
30” (76.2 cm)
36”
36” (91.4 cm)
48”
48” (121.9 cm)
60”
60-1/4” (153.0 cm)  
Note: If a range hood is installed, wall cabinets above
the range have a different minimum clearance height.
Note: Minimum clearance for back wall is 0” with
backguard or high-shelf.
Important: This range comes standard
with an Island Trim. There must be a
minimum of 6” (15.2 cm) clearance from
rear of range to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.