Sub-Zero IW30 Installation Instruction

Page of 44
subzero.com   
|
   5
SITE PREPARATION
HOME SECURITY CONNECTION
If the unit will be connected to a home security system, low-
voltage leads must be provided to the unit. Two connectors 
are located behind the top trim. Provide 10'
 (3 m)
 minimum 
lead wires for each connector, exiting the back wall near the 
electrical receptacle.
Remove the top trim by disengaging the trim from the hinge 
side of the unit. Rotate the trim and remove the trim pin from 
the handle side vertical support. Refer to the illustrations 
below. Use spade terminals or wire nuts to make proper 
wiring connections. Refer to the following color codes:
  Normally open contacts—white with red stripe wire. 
  Common—gray with white stripe wire.
 CAUTION
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used 
to switch line power. Any unused terminals should be 
completely insulated and all wires should be secured 
away from conductive or moving components.
Electrical
Installation must comply with all applicable electrical codes. 
The electrical supply must be located within the shaded 
area shown in the illustration and chart below. A separate 
circuit, servicing only this appliance is required. A ground 
fault circuit interrupter (GFCI) is not recommended and may 
cause interruption of operation.
The electrical outlet must be positioned with the grounding 
prong to the right of the thinner blades.
 CAUTION
The outlet must be checked by a qualified electrician to 
be sure that it is wired with the correct polarity. Verify 
that the outlet is properly grounded.
 WARNING
Do not use an extension cord, two-prong adapter or 
remove the power cord ground prong.
ELECTRICAL REQUIREMENTS
Electrical Supply 
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
WIDTH
A
18"
 
Models
6"
 (152)
24"
 
Models
9
1
/
2
"
 (241)
30"
 
Models
12
1
/
2
"
 (318)
A
1
/
4
(6)
1
/
4
(6)
4
1
/
4
"
(108)
4
1
/
2
"
(114)
FLOOR
LEFT SIDE
OF OPENING
 
Electrical supply location.
 
PIN
 
Top trim—hinge side.
 
Top trim—handle side.