Friedrich WE10D33 Installation Instruction

Page of 43
8
Won’t cool
Won’t heat (for heat/cool models only)
If the unit operates, but won’t heat, determine if the control settings are 
 ti
 fi
 e
ni
m
r
et
e
d
 o
n
oi
ti
s
o
p
 r
e
m
r
a
w
 a
 o
ta
ts 
o
m
 r
e
h
e
h
ts
uj
d
A
 .t
c
e
rr
o
c
operates. Also, check the fi 
.d
e
d
e
e
fi 
,y
l h
g
u
r
o
h
t t
n
a
el
d
n
r
et
Odors in heating (for heat/cool models only)
You may notice a smoke odor the fi  rst time the heater element comes 
on. This is common in any type of heat system when fi  rst turned on 
for the winter. The odor comes from dust and other particles that 
accumulate during the warm months. The odor will dissipate quickly.
Won’t run
If the unit fails to operate, check to see if the power cord is fi  rmly 
plugged in. Check for blown fuses, tripped circuit breakers or a 
tripped LCDI Device (Refer to LCDI reset instructions in the Power 
cord information 
section). Restore the circuit breaker or replace the 
blown fuse with a proper size "TIME-DELAY" fuse. The proper fuse 
size is shown on page 
3
 in these instructions. After restoring the 
current supply to the unit, wait three minutes before unit will restart.
Troubleshooting tips and 
home maintenance
If the unit operates, but won’t cool, determine if the controls are 
properly set. Set the  thermost to a cooler position in order to check 
control settings. Check the filter and clean it thoroughly, if 
needed. Check to see if the vent door is closed. 
Certain operating conditions may produce indoor coil frost. During 
the cooling operation, a dirty  filter or restricted air distribution in 
combination with cool, damp weather could cause such an occurrence. 
Should the indoor coil frost over while cooling, set the control to FAN 
and keep it running until the frost on the coil is gone. Setting the 
ther mo stat to a slightly warmer position will probably keep the coil
from frosting over again.
The decorative front of your Friedrich room air conditioner, as well 
as the complete cabinet, may be cleaned with warm water and mild 
detergent. Under adverse operating conditions, the indoor and outdoor
coils and base pan may require periodic cleaning to maintain eficient 
operation.  Your Friedrich dealer should be called when this service 
is required.
STEP 1  The wall opening required for a WSE SLEEVE is 17 ¼" 
high by 27 ¼" wide.
STEP 2  LINTELS must be used in opening of brick veneer and 
masonry walls to support the material above the WSE   
SLEEVE.  The following considerations should also be given:
ITEM NO.
QTY.
1
DESCRIPTION
SCREW, #12A x 2"
7
Falling Object Hazard
WARNING
Not following Installation Instructions for 
mounting your air conditioner can result 
in  property damage, injury, or death.  
B.  Adjustable SUBBASE (SB) or other unit support must be provided 
for panel wall type construction and for walls less than 8" thick.
A.  A minimum distance of 1" must be allowed on all sides of the unit 
to adjacent wall and  floor.  Where the subbase is required, the 
minimum distance from the  floor to the sleeve must be 3 ½". 
To minimize  chances of short cycling of the compressor, the 
minimum clearance between the ceiling and the top of the unit 
should be 24". 
(See figure 5)
INSIDE 
WALL
7/8" MINIMUM BEYOND 
INSIDE WALL
WSE SLEEVE
LINTELS
5" (127 mm)
5" (127 mm)
WALL MOUNT 
SCREW LOCATIONS
DRAIN 
EXTENSION
9/16" MINIMUM
BEYOND OUTSIDE WALL
OUTSIDE WALL
24" MINIMUM REQUIRED 
FROM TOP OF UNIT TO CEILING
1" MINIMUM
3 1/2" FOR SUBBASE
5 1/2" MAXIMUM FOR SUBBASE
1" MINIMUM SPACING REQUIRED 
ON ALL SIDES OF UNIT
Figure 5 
Side View
Installation Instructions for WSE 
Sleeve 
(WSE Sleeve Accessory Sold 
Separately)