Exhaust Option: When viewed from the front 
of the unit, exhaust 3-way via rear, left and 
bottom. Dryer is shipped exhausted to the 
rear. Alternate exhausting knockouts are 
supplied.
Gas:  An individual, properly-grounded 
branch circuit, with a three-prong grounding-
type receptacle, protected by a 15 or 20 
amp circuit breaker or a time-delay fuse is 
required.
Gas Dryer Electric Rating: 120V, 60Hz, 9A
Gas (BTU/HR): 16,000. Factory-equipped for 
natural gas. Tested for LP gas. LP gas supply 
requires a conversion kit. Check installation 
instructions for correct kit and have a 
qualified gas technician install a conversion 
kit. See dryer ducting information for proper 
installation.
Note: Dryer wall outlet must be located within 
36" of service cord entry and accessible when 
dryer is mounted in position.
Installation Information: For complete 
information, see installation instructions 
packed with your dryer.
Dimensions and Installation Information (in inches)
Special Installation Requirements
Alcove or Closet Installation:
 
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label  
  on the dryer back. 
• The dryer MUST be exhausted to the outside. 
•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. 
•  Closet doors must be louvered or otherwise ventilated and must contain a minimum 
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and 
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. 
•  The installation must conform with the local codes, or in the absence of local codes, 
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
•  Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.
Specification Created 1/15
GTD81GSSJ/GSPJ
GE
®
 7.8 cu. ft. capacity gas dryer with aluminum alloy drum