Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded 
area shown in the illustration below. A separate circuit, 
servicing only this appliance is required. A ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause 
interruption of operation.
IMPORTANT NOTE:
 The electrical outlet must be placed so 
the grounding prong is to the right of the thinner blades. 
The outlet must be flush with the back wall.
ELECTRICAL REQUIREMENTS
Electrical Supply 
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
 WARNING
Do not use an extension cord, two-prong adapter or 
remove the power cord ground prong.
Preparation
To operate properly, the door must open a minimum of 90°. 
Use a minimum 3"
 (76)
 filler in corner installations to assure 
a 90° door opening.
Uncrate the unit and inspect for damage. Remove and 
recycle packing materials. Do not discard the kickplate, anti-
tip bracket, hardware and the leveling legs which hold the 
wood base to the bottom of the unit.
MODEL 424G / 424FSG SITE PREPARATION
3" 
(76)
15
1
/
2
"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
 
Electrical supply location.