PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
 
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 08/15/14   Page 2/4
Recommended
gas and electrical
service location,
consult local code
B
10” (25.4 cm) to
combustible side 
wall min. both sides
1/2” (1.3 cm)
overhang,
both sides
1 1/2” (3.8 cm)
typical countertop
thickness
7 3/4” 
(19.7 cm)
36” (91.4 cm)
typical
Mounting platform
1”  (2.5 cm) min.
thickness
Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted.
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
CABINET/COUNTERTOP DIMENSIONS -
ISO VIEW
continued on following pages...
See note 2
2 See Cabinet/Countertop Dimensions - Top View 
3 This specification not applicable for cabinets more 
than a horizontal distance of 10” (25.4 cm) from the 
edge of the rangetop.
1 Vertical to combustible surface from rangetop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances. 
C
13” (33.0 cm) 
max.
3
Top of
finished
counter
Grate 
level
Grate 
level
15” (40.6 cm)
min.
1, 3
30” (76.2 cm)
min.
1
Cutout for 
utility access
Model No.
B
C
DYRTP366
36” (91.4 cm)
36” (91.4 cm)* 
42” (106.7 cm)**
DYRTP486
48” (121.9 cm)
48” (121.9 cm)*  
54” (137.2 cm)**