Lynx L700PSR Use & Care Manual

Page of 40
SEDONA CARE & USE/INSTALLATION
  
|
23
BEFORE YOU START... continued
The enclosure should have ventilation holes to prevent 
gas build-up in the event of a leak. The deck ledges and 
counter should be flat and level. (refer to ANSI Z21.58 
Standard for Outdoor Cooking Gas Appliances, Section 1.7 
Enclosures For Self Contained LP-Gas Supply Systems)
This grill requires that a 120 volt, 60 hertz, 15 amp GFI 
certified outlet be installed by a qualified electrician. 
CLEARANCE TO COMBUSTIBLES 
Minimum clearance from the sides and back of the grill to 
adjacent combustible construction below the counter top 
surface are 12” from the sides and back. 
Dégagement minimal entre les parois latérales et l’arrière 
de l’appariel et la construction combustible au-dessous du 
panneau supérieur de l’appareil (30 cm à partir des parois 
latérales et 30 cm à partir de l’arrière). 
Minimum clearance from the sides and back of the grill to 
adjacent combustible construction extending above the 
counter top surface are 18” from the sides and back. 
Dégagement horizontal minimal entre les parois latérales 
et l’arrière de l’appariel et la construction verticale 
combustible au-dessus de l’appareil (45.7 cm à partir des 
parois latérales et 45.7 cm à partir de l’arrière). 
Do not use this appliance under overhead combustible 
surfaces. 
Ne pas utiliser cet appareil sous une surface combustible. 
A minimum of 6” of clearance is needed on the left side of 
the grill above the counter top for the motor and skewer. 
If the grill is to be placed in a combustible enclosure an 
approved insulating jacket is necessary. Order model 
number LIJ400, LIJ500, LIJ600 or LIJ700 depending on 
your grill size.
REAR HOOD CLEARANCE
A 3" clearance is required behind the grill to allow the front 
hood to open. 
The grill exhausts combustion products and cooking 
greases to the back. Never locate the grill where this 
exhaust will be difficult to clean. 
When using a Lynx Quick Disconnect device (LQD) and a Lynx Insulating Jacket the flexible hose must not 
contact any portion of the firebox section of the grill. It is recommended that the installer use best fitting 
practices to hard pipe the connection outside of the insulating jacket through one of the openings  in 
the insulating jacket. This will locate the hose outside of the unit and prevent contact with hot surfaces. 
Overheating the LQD hose can cause separation and gas leaks that pose a potential fire hazard.