GE AGBS45DEF Specification Sheet

Page of 2
Dimensions and Installation Information (in inches) 
For answers to your Monogram
®
 or GE
®
  
appliance questions, visit our website at 
geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation  
of the range.
* ADA qualified based 
on Uniform Federal 
Accessibility Standards
*
Optional Gas Range Accessory Drip Pans for Sealed and 
Standard Burner Models  
(Available at additional cost) To order these accessory drip pans,  
call toll-free 800-626-2002 
Electrical Rating: 120V, 60Hz, 5A
Installation Information: Before installing, consult installation 
instructions packed with product for current dimensional data.
Note: 30" ranges conform to U.L. requirements for 0" spacing from 
 adjacent walls below countertops. To reduce possible scorching of 
walls,  engineering  recommends a minimum of 1-1/2" spacing to 
allow for possible extended, high heat, no-load heating element 
operation.
Specification Created 5/13
330461
AGBS45DEF 
GE Artistry
 Series
 
30" Free-Standing Gas Range
 
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge of
the range side
panel forward
from cabinet
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 240V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
46 3/8"
28 3/4"
w/ handle
26 1/4"
w/o handle
30"
36 to 36 1/4"
44 1/2"
8 1/2"
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge of
the range side
panel forward
from cabinet
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 240V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
46 3/8"
28 3/4"
w/ handle
26 1/4"
w/o handle
30"
36 to 36 1/4"
44 1/2"
8 1/2"
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge of
the range side
panel forward
from cabinet
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
2"
30"
30"
13"
2"
36"
0"
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 240V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
46 3/8"
28 3/4"
w/ handle
26 1/4"
w/o handle
30"
36 to 36 1/4"
44 1/2"
8 1/2"