Dacor DYWS4 Installation Instruction

Page of 12
8
8.  Find the gas regulator assembly shipped with the 
unit. 
9.  Make sure the regulator adjustment knob is turned 
all the way in the 
OFF direction.
10. Plug the end of the gas tubing leading to the wine 
dispensing system into the gas regulator assembly.
11.  Remove the plastic cap from the top of the argon 
gas cylinder (must be ordered separately, see page 
6).
12. Insert the top of the gas cylinder into the bottom of 
the gas regulator assembly and turn it clockwise 
until it is snug. Do not overtighten.
13. Turn the regulator knob in the 
On direction until it 
stops.
14. Open the door on the front of the unit. Swing the 
spout cover to the up position. 
15. Make sure the power switch, located on the left 
side of the bottle bay, is slid all the way down, to 
the 
OFF position.
16. Plug the power cord into the electrical outlet.
17. Slide the main power switch all the way up to the 
On position.
18. The unit will run through a series of self-tests, 
which will take several seconds. Once this process 
is completed, the blue lights on the control panel 
will come on, indicating that the wine dispensing 
system is ready for use. 
IMPOrTAnT: When the 
system is powered up for the first time, 
LOCKeD 
will appear on the display. See Unlocking the 
Control Panel in the operation section of the use 
and care manual for unlocking instructions.
19. Push up on the spout cover release lever on the 
bottom of the spout cover. Hold the lever up as you 
lower the cover down into place. 
CAuTIOn: Do not 
push down on the spout cover without pushing up 
on the lever. Damage to the lever will result.
20. Once the spout cover is closed, close the bottle 
bay door. Push in slightly just above the lock until it 
snaps shut.
Installation Instructions
Regulator 
adjustment 
knob
Gas supply 
line from wine 
dispensing 
system
Regulator 
assembly
Argon 
gas  
cylinder
Spout cover 
release lever 
(on bottom of 
spout cover)
Switch Positions
ON 
RESERVED 
NOT USED 
OFF
Main Power Switch 
(under spout cover)
For use by 
authorized 
service 
personnel only