Dacor RNO130C208V Design Guide

Page of 2
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
RNO, RNOV
Revised 05/22/14   Page 1/2
Renaissance
®
 27” and 30” Wide 
Single Wall Ovens
Document # PG01-015
Model
(A) Overall 
Width
(B) Chassis 
Width
(C) Overall 
Height
(D)* Chassis 
Height
(E) Control 
Panel 
Overlay
RNO[V]127
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
27 3/4”
(70.5 cm)
27 3/8”
(69.5 cm)
3/8”
(1.0 cm)
RNO[V]130
29 7/8”
(75.9 cm)
28 3/8”  
(72.1 cm)
27 3/4”
(70.5 cm)
27 3/8”
(69.5 cm)
3/8”
(1.0 cm)
* To top of chassis notch behind control panel
(F) Utility 
Cutout Width
(G) Utility 
Cutout Height
(H) Utility 
Cutout Depth
(J) Control 
Panel Depth
(K) Chassis
Depth
(L) Control
Panel Notch
Depth
(M) Notch  
Height
6 1/2”
(16.5 cm)
5”
(12.7 cm)
7 7/8”
(20.0 cm)
3/4”
(1.9 cm)
24”
(61.0 cm)
1/2”
(1.3 cm)
3/4”
(1.9 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
 WARNING
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information. 
•  This appliance must be installed in accordance with the 
accompanying installation instructions.
Control panel
side view
Control panel 
front
Top of
chassis
Top of 
chassis
Utility
cutout
Conduit:
60” (152 cm) 
long
C
J
B
H
G
F
A
K
E
L
M
D
2 3/8”
(6.0 cm)
1 7/8”
(4.8 cm)
Handle Dimensions
Epicure
Millennia 
(Order kit #AROVH30S)
Flush
21 1/2”
(54.6) cm
ELECTRICAL SPECIFICATIONS
Model
Dedicated Circuit 
Requirements
Total Connected Load
RNO[V]127
240 Vac 60 Hz., 4-wire,***  
30 Amp.
240 Vac 60 Hz,
19.0 Amp., 4.7 kW
RNO[V]130
240 Vac 60 Hz., 4-wire,***  
30 Amp.
240 Vac 60 Hz,
24.5 Amp., 6.0 kW
*** Two 120 Vac hot (L1 and L2), one neutral, one ground
The above specifications are for reference only. See the appliance data 