Dacor DTO230S208V Design Guide

Page of 2
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DTO, DTOV
Document # PG01-014
Revised 06/05/14   Page 1/2
Distinctive
®
 27” and 30” Wide 
Double Wall Ovens
Model
(A) 
Overall 
Width
(B) 
Chassis 
Width
(C) Overall 
Height
(D)
Chassis 
Height
(E) Control 
Panel 
Overlay
DTO[V]227
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
50 1/8”
(127.3 cm)
49”
(124.5 cm)
1 1/8”
(2.9 cm)
DTO[V]230
29 7/8”
(75.9 cm)
28 3/8”  
(72.1 cm)
50 1/8”
(127.3 cm)
49”
(124.5 cm)
1 1/8”
(2.9 cm)
(F) Utility 
Cutout Width
(G) Utility 
Cutout Height
(H) Utility 
Cutout Depth
(J) Control 
Panel Depth
(K) Chassis 
Depth
6 1/2”
(16.5 cm)
5”
(12.7 cm)
7 7/8”
(20.0 cm)
1 1/4”
(3.2 cm)
23 1/2”
(59.7 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
 WARNING
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information. 
•  This appliance must be installed in accordance with the 
accompanying installation instructions.
21 7/8”
(55.6) cm
C
A
Conduit:
60” (152 cm) 
long
D
J
B
H
G
F
Top of 
chassis
Utility
cutout
K
Control panel
side view
Control panel 
front
Top of
chassis
E
3 1/2”
(8.9 cm)
3 3/16”
(8.1 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
Handle Dimensions
Epicure
Millennia 
(Order kit #AROVH30S)
Flush
ELECTRICAL SPECIFICATIONS
Model
Dedicated Circuit 
Requirements
Total Connected Load
DTO[V]227
240 Vac 60 Hz., 4-wire,* 
40 Amp.
240 Vac 60 Hz,
26.2 Amp., 6.4 kW
DTO[V]230
240 Vac 60 Hz., 4-wire,* 
40 Amp.
240 Vac 60 Hz,
26.6 Amp., 6.4 kW
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The above specifications are for reference only. See the appliance data 
plate for exact specifications.