Vent-a-Hood PRH18M42SS Specification Sheet

Page of 1
VP566 transition centers 
outlet over top of hood
PRH18-M/PRXH18-M  This model is available with halogen lighting. X in part number indicates 27” 
depth. M600 and M1200 blowers are sold separately. Features stainless steel baffle filters.
WALL MOUNT RANGE HOOD SPECIFICATIONS
*Exceeding recommended 
mounting height may 
compromise performance.
Single Blower
(Top View)
UL
C
US
R
M1200 Connection Diagram
Recommended
Mounting Height*
VP566 Transition (Included)
With M1200 Dual Blower

Electrical


10" Round
Centerline
of Hood
6" Round

Electrical

Centerline
of Hood






10” Round
Dual Blower
(Top View)
M600 Connection Diagram
Electrical/Mechanical Specifications For Blower Units
Model
Volts
Amps*
Hz
CFM
SP@0.0"
CFM
SP@0.1"
CFM
SP@0.25"
CFM
SP@0.5"
CFM
SP@0.75"
Minimum Round
Duct Size
M600 Single
115
5.0
60
630
625
615
600
580
6" (28 in.
2
)
M1200 Dual
115
10.0
60
1035
1015
1000
955
915
10" (79 in.
2
)
* Add 0.5 amp for each halogen light. Hoods are available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54"-66").
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0810A
Available Widths
30", 36", 42", 48",
54", 60", & 66"
PR(X)H18-M






SPEED
CFM @ 0.1" S.P.
M600*
M1200
1
240
420
2
300
645
3
500
865
4
625
1015
* A special harness is available that 
limits the M600 blower to 300 CFM.