Lynx L42ASFRNG Owner's Manual

Page of 48
29
note:
lynx built-in grills are intended 
either for installation in a 
built-in enclosure constructed 
of non-combustible materials 
or for an installation in a built 
in enclosure constructed of 
combustible material when 
installed with a lynx insulating 
jacket (liJ).
for non-combustible applica-
tions, the grill drops into the 
opening shown in the cutout 
detail drawing 
(see indeX: “gas 
Requirements”)
 and hangs from 
its counter-top trim. a deck is 
not required to support it from 
the bottom. 
when using the insulated 
jacket in a combustible 
enclosure, the jacket must be 
supported from the bottom by 
a ledge on each side or a full 
deck beneath the jacket.
(See INDEX: “Gas Requirements”)
 
pay special attention to the 
provisions shown for gas line 
hook-up.
the enclosure should have 
ventilation holes to prevent 
gas build-up in the event of 
a leak. the deck ledges and 
counter should be flat and 
level. (refer to ansi Z21.58 
standard for outdoor cooking 
gas appliances, section 1.7 
enclosures for self contained 
lp-gas supply systems)
This grill requires that a 120 
volt, 60 hertz, 15 amp gfi 
certified outlet be installed by 
a qualified electrician. 
clearance to com-
bustIble materIals: 
minimum clearance from the 
sides and back of the grill to 
adjacent combustible con-
struction below the top of 
unit are 12” from the sides 
and back. 
dégagement minimal entre 
les parois latérales et l’arrière 
de l’appariel et la construc-
tion combustible au-dessous 
du panneau supérieur de 
l’appareil (30 cm à partir des 
parois latérales et 30 cm à 
partir de l’arrière). 
minimum clearance from 
sides and back of unit to 
adjacent combustible con-
struction extending above the 
unit is 18” from the sides and 
back. 
dégagement horizontal 
minimal entre les parois 
latérales et l’arrière de 
l’appariel et la construction 
verticale combustible au-
rear Hood clearance:
A 3 inch clearance is required behind the grill to allow the front 
hood to open. 
the grill exhausts combustion products and cooking greases to 
the back. Never locate the grill where this exhaust will be difficult 
to clean. 
(3” min)
dessus de l’appareil (45.7 cm 
à partir des parois latérales et 
45.7 cm à partir de l’arrière). 
do not use this appliance 
under overhead combustible 
surfaces. 
ne pas utiliser cet appareil 
sous une surface combus-
tible. 
a minimum of 6” of clearance 
is needed on the left side of 
the grill above the counter 
top for the motor and skewer. 
if the grill is to be placed into 
a combustible enclosure, an 
approved insulated jacket 
is necessary and is available 
only from your lynx dealer. 
lynx insulated jackets have 
been designed and tested 
specifically for your Grill.