ELECTRICAL CONNECTIONS
warning - electrIcal groundIng
 
► product installation must meet local electric codes or, in the absence of local codes, the latest 
edition of the national electrical code ansi/nfpa no. 70 or the canadian electrical code 
cga 1.6b2005.
 
► use only a ground fault interrupter (gfi) protected circuit with this outdoor cooking gas ap-
pliance. 
 
► Important:  When connecting your rotisserie motor, first connect the motor to the grill and 
then plug the grill into the outlet.
 
► This grill is equipped with a three prong (grounding) electric plug for your protection against 
shock hazard and must be plugged directly into a properly grounded three prong outlet. 
neVeR cut or remove the grounding prong from this plug. 
 
► Use only extension cords with a 3 prong grounding plug, rated for the power of the equip-
ment, and approved for outdoor use with a “w-a” marking.
 
► to protect against electric shock, do not immerse any part of the power cord, an extension 
cord or any plugs in water or other liquid.
 
► unplug the product from the outlet when not in use and before cleaning. allow it to cool 
before putting on or taking off parts.
 
► do not let the cord hang over the edge of a table or touch hot surfaces.
 
► do not use an outdoor cooking gas appliance for purposes other than intended.
 
► do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the 
appliance malfunctions or has been damaged in any manner. contact the manufacturer for 
repair.
Installation requires an 
outdoor 120Vac 15a gfi 
(ground fault interrupter) 
electrical outlet adjacent to 
the grill. 
the gfi outlet features an 
internal breaker that reduces 
shock hazard. this type of 
outlet should be installed by 
a qualified electrician either 
inside the island enclosure 
for built-in units, or near the 
location where a free-standing 
unit will be used.  
for built-in grills, the supplied 
12V transformer is connected 
to the grill during installation. 
when installing the trans-
former to the grill be careful 
to prevent the wiring and 
transformer from contacting 
any hot surfaces behind or 
below the grill. it is recom-
mended that the transformer 
be located below the grill in 
a readily accessible location. 
Be sure to provide adequate 
access to facilitate service if 
the transformer or connec-
tions should need future main-
tenance.
if the electrical system fails to 
operate, a connection may 
have come loose in shipping 
or the gfi may have tripped, 
requiring a reset. See the 
troubleshooting section for 
more details. 
connectIon to ac