Drip pan 
•  When the compressor stops working, water drops will drain through the 
outlet in the inner back wall into the drain pan (above the compressor). 
•  If the drain pan needs to be cleaned, pull the drain pan forward gently 
and reinstall it after cleaning. 
 
TROUBLESHOOTING 
 
If your cooler does not work properly, please note the following suggestions 
before you attempt to repair. 
 
Cooler does not work: 
•  Check the electrical outlet for power, and that the plug is properly 
inserted. 
•  Check the condenser for proper cleaning. 
•  The circuit breaker is tripped or the fuse is blown. 
Cooler makes too much noise: 
•  Check that the cooler is level. 
Compressor turns on and off frequently: 
•  The room temperature is higher than normal. 
•  The door is not closed completely. 
•  The door gasket is not sealed well. 
•  There is insufficient clearance around the cooler. 
•  The temperature is not set properly. 
•  The cycling frequency will reduce when all of the cans reach the set 
temperature. 
The following is not a malfunction: 
•  It is normal to hear gurgling sounds caused by the flow of refrigerant 
when each cooling cycle ends. 
 
CIRCUIT DIAGRAM 
 
Computerized Controller
Overload
Protector
Compressor
C
S
M
PTC Starter
Starter
Impedance
coil
Control Enclosure
115V 60Hz
Sensor
Starter
Impedance
coil
 