Viking VCBB5363ERBU Installation Guide

Page of 20
33
32
Locate water filter door. The door is located under 
the Adjustable Cold Zone™ handle.
Push upper left corner of door to release latch 
and pull door downward.
Insert filter cartridge into circular opening in filter
housing. Rotate clockwise gently until filter stops.
Close water filter door.
Flush 3 gallons through filter before use (flush
approximately 3 minutes). If water spurts occur,
continue to run water until water runs steady.
Additional flushing may be required in areas with poor
quality water.
NOTE: Allow 1-2 minute delay in water dispersal to
allow internal water tank to fill.
24
2
1
25
1
3
2
26
27
   Water Filter Installation 
(Side-by-Side with Dispenser)
Water Filter System Specification and 
Performance Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration of less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors
built-in for unmetered usage for health claims only.)
*Based on the use of Cryptosporidium parvum oocysts
Operating Specifications
Capacity:  
Certified for up to 750 gallons (2,838 L); up to nine months
Pressure Requirement:  
20 - 120 psi (1.4 - 8.2 bar)
Temperature: 33-100
o
F (0.6 - 37.8
o
C)
Flow rate:
0.78 gpm (2.9 l/min.)
Check for compliance with the state and local laws and regulations.
Note: 
While the testing was performed under standard laboratory conditions, actual performance may vary.  
Must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
Installation instructions, parts and service availability, and standard warranty are included with the product when
shipped. This drinking water system must be maintained according to manufacturer’s instruction, including
replacement of filter cartridges.
Manufactured by:
3M Purification Inc.
400 Research
Parkway
Meriden, CT  06770
System tested and certified by NSF International
against Standard 42 for the reduction of chlorine
taste and odor, particulate Class I and Standard 53
for the reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Abestos.
Contaminant
Reduction
Average
Influent
NSF Specified
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentrtation
Max Permissible
Product Water
Concentration 
NSF
Reduction
Requirements
NSF Test
Report
Chlorine Taste and 
Odor
2.0 mg/L
2.0 mg/L + 10%
97.5%
0.05 mg/L
N/A
> 50%
J-00056501
Nominal Particulate
Class I, >0.5 to < 
1.0 µm
13,666,667
pts/mL
At least 10,000
particles/mL
98.9%
143,333 pts/mL
N/A
> 85%
J-00056506
Asbestos
96 MF/L
107 to 108 fibers/L;
fibers greater than
10µm in length
>99%
<1 MF/L
N/A
> 99%
J-00056511
Atrazine
0.010 mg/L 0.009 mg/L + 10%
89.3%
0.001 mg/L
0.003 mg/L
N/A
J-00056512
Cyst*
122,500
cysts/L
Minimum 50,000
cysts/L
99.99%
1 cyst/L
N/A
> 99.95%
J-00056513
Lead @ pH 6.5
0.153 mg/L 0.15 mg/L + 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00056515
Lead @ pH 8.5
0.150 mg/L 0.15 mg/L + 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00058784
Lindane
0.002 mg/L 0.002 mg/L + 10%
97.8%
0.00004 mg/L
0.0002 mg/L
N/A
J-00058969
Mercury @ pH 6.5
0.006 mg/L 0.006 mg/L + 10%
95.0%
0.0003 mg/L
0.002 mg/L
N/A
J-00058785
Mercury @ pH 8.5
0.006 mg/L 0.006 mg/L + 10%
88%
0.0007 mg/L
0.002 mg/L
N/A
J-00058783
Toxaphene
0.015 mg/L 0.015 mg/L + 10%
93.2%
0.001 mg/L
0.003 mg/L
N/A
J-00056531
Turbidity
10.8 NTU
11 + 1 NTU
98.7%
0.153 NTU
0.5 NTU
N/A
J-00058972