Viking FDBB5363ER Installation Guide

Page of 26
19
18
One 2”x 4” mounting boards
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim 
behind the mounting board by the difference.
    
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
  
Anti-Tip Location
79-3/8”
(201.6 cm) min.
to bottom of 
anti-tip boar
d
80-1/2”
(204.6 cm) max.
to bottom of 
anti-tip boar
d
41”
(104.1 cm)
3-1/2”
(8.9 cm)
1-1/2”
(3.8 cm)
Anti-Tip Dimensions 
(Side-By-Side)
9”
(22.9 cm)
73-3/8”
(186.4 cm)
82–7/8”
(210.5 cm) min.
anti-tip boar
d &
opening height
84–1/16”
(213.5 cm) max.
anti-tip boar
d &
opening height
48”
(121.9 cm)
24”
(61.0 cm)
Electric Outlet Location
Water Line Entry Area
47-1/2”
(120.7 cm)
6-3/4”
(17.1 cm)
7-5/8”
(19.4 cm)
3”
(7.6 cm)
5/8”
(1.5 cm)
5/8”
(1.5 cm)
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
10-3/4”
(27.3 cm)
1”
(2.5 cm)
3-5/8”
(9.2 cm)
Optional floor 
water line entry
See anti-tip boar
d installation
    
6”
(15.2 cm)
9”
(22.9 cm)
Cutout Dimensions 
(Side-By-Side)
48” Side-By-Side
48” Side-By-Side
One 2”x4” mounting board 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind
the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height. 
Note: Top of unit must be placed firmly under anti-tip board.