Dacor DDW24S Installation Instruction

Page of 20
5
Dishwasher Cutout - Front View
Minimum Door Clearance
Preparing for Installation
Cutout tolerances: +1/16” (+1.6 mm), -0
2” (5.1 cm) Min. 
clearance
Preparing the Location
 WARNING
Follow all cabinet dimensions shown to insure safe 
operation. All minimum product dimensions must 
be met or exceeded (see page 3). Dimensions 
shown provide the required clearances.
•  The cabinet must enclose the dishwasher on the 
top, back and both sides.
•  Carefully check the location where the 
dishwasher is to be installed. Put it in a location 
with convenient access, close to the kitchen 
sink for easy water supply and drain connection. 
The power supply shall meet the Electrical 
Specifications on page 4. Also, the electrical 
outlet or junction box shall be installed close by 
in a cabinet adjacent to the location selected so 
that the power cable can be disconnected without 
removing the appliance from the cutout. 
•  The electrical wiring, water supply and drain 
lines must enter through the area indicated by 
the shading on the illustration at right. Preferably, 
they should come through the right side of the 
cabinet. 
•  The access hole(s) in the cabinet for the power 
cord and water line shall be no bigger than 1-1/2˝
(3.8 cm) in diameter. The access hole for the 
drain hose shall be no bigger than 2˝ (5.0 cm)
in diameter. The access holes for all three must 
be round and smooth. If the partition is metal, it 
needs to be covered with an edge protector. Call 
Dacor for the part number of an approved edge 
protector.
•  The opening through the partition between the 
drain connection and the dishwasher cutout 
must be higher than the disposer or waste tee 
connection (see page 6) and lower than 35” 
(88.9 cm).  
•  Plan the installation so that the appliance can be 
removed easily if service is required.
•  If the dishwasher is installed in a corner, allow a 
minimum clearance of 2” (5.1 cm) from the side 
wall so the door can open. See diagram, right.
•  The floor must be solid, level and all cutout 
surfaces must be at right angles. In the interest 
of safety, the surrounding cabinet must have 
sufficient material for attachment of the anti-tip 
brackets (see page 13).
* If the height of the existing cutout is too low:
 - Check to see if the cabinet face can be trimmed 
at the top. In many cases, when a non-standard 
size dishwasher has been installed previously, 
there is enough room inside the cabinet once the 
cabinet face is modified.
 - The dishwasher can be shortened 1/4” (6.0 
mm) by not installing the plastic feet on the unit 
as shown on page 9. Extra care must be 
taken if the feet are not installed. Dacor is not 
responsible for floor damage during installation.
 - The dishwasher can be shortened 1/4” (6.0 mm) 
by removing the trim pieces that surround the 
wash compartment opening. 
NOtE: Doing so will 
create a gap of 1/4” (6.0 mm) on the right and 
left side of the door. 
24” (61.0 cm)
24”
(61.0 cm)
4” (10.2 cm)
2” (5.1 cm)
34 1/2” 
(87.6 cm)
to
36 1/2” 
(92.7 cm)
5 3/8”
(13.6 cm)
*
2” (5.1 cm)