Installation Considerations
Instructions are based on standard American cabinets 36" 
(914 mm) high and 24" (609 mm) deep with a 25" (635 mm) 
countertop. If using non-standard cabinets, alter 
dimensions accordingly.
Cabinet opening bottom must be able to support 110 lbs. 
(50 kg).
Wall-Mounted Installation
THERMADOR
®
 warming drawers may be installed below 
any THERMADOR single or double built-in oven. A 
minimum space of 1" (25.4mm) is recommended between 
the bottom of the oven and the top of the warming drawer. 
Under-Counter Installation
THERMADOR warming drawers may also be installed 
below any THERMADOR electric or non-professional gas 
cooktop as long as there is no contact between the bottom 
of the cooktop and the top of the warming drawer. When 
installing below a THERMADOR induction cooktop, a 
minimum 1" (25.4 mm) air gap must be maintained 
between the bottom of the cooktop and the top of the 
warming drawer. 
When installing below a THERMADOR PROFESSIONAL
®
 
rangetop, a minimum 2¾" (70 mm) air gap must be 
maintained between the bottom of the rangetop and the top 
of the warming drawer. 
WDC30JS
WDC30JP
Specifications and Dimensions
WDC30JS
WDC30JP
Without Door
Product Width
Product Height
Product Depth w/ gasket
29½" (749 mm)
10½" (267 mm)
22" (559 mm)
Cutout Width
Cutout Height
Cutout Depth
28½" (724 mm)
10" (254 mm)
23" (584 mm)
Door Width
Door Height
Door Depth
29¾" (756 mm)
11¼" (286 mm)
1
7
/
16
" (37 mm)
Clearance for door
opening
22
13
/
16
" (580 mm) for JP
22
7
/
16
" (570 mm) for JS
Electrical Supply
Required Circuit Breaker
Wattage
Power Cord Included
Power Cord Length
120 V AC, 60Hz
15 Amp
930
120V-3-Wire
72" (1,829 mm)
Shipping Weight
80 lbs (36 kg)