Lynx L36ASRLP Owner's Manual

Page of 48
46
model-specIfIc btu outputs
model 
H burner 
rotIsserIe 
prosear 
total Input
l27(f) 
2 @ 25,000 btu 
50,000 btu/Hr
l27(f)r 
2 @ 25,000 btu 
1 @ 14,000 
64,000 btu/Hr
l27ps(f)r 
1 @ 25,000 btu 
1 @ 14,000 
1 @ 23,000 
62,000 btu/Hr
l30r(f) 
2 @ 25,000 
1 @ 14,000 
64,000 btu/Hr
l30ps(f)r 
1 @ 25,000 
1 @ 14,000 
1 @ 23,000 
62,000 btu/Hr
l36r 
3 @ 25,000 
1 @ 14,000 
89,000 btu/Hr
l36ps(f)r 
2 @ 25,000 
1 @ 14,000 
1 @ 23,000 
87,000 btu/Hr
l42r 
3 @ 25,000 
1 @ 16,000 
91,000 btu/Hr
l42ps(f)r 
2 @ 25,000 
1 @ 16,000 
1 @ 23,000 
89,000 btu/Hr
l54ps(f)r 
3 @ 25,000 
2 @ 14,000 
1 @ 23,000 
126,000 btu/Hr
maxImum runs for all  
applIances on supply lIne
Run length
3/4” pipe
(in feet)
max Btu for all  
appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135.000
70
123,000
80
115,000