Kenyon B80101 Owner's Manual

Page of 17
For future reference, please record the serial number of your
cooktop here:                                            
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.  The 
following table provides the correct voltage, amperage and frequency that must be supplied to the 
cooktop.
  
 
The supply must be from an individual grounded circuit that is protected by a circuit breaker and 
rated per the specifications for the various models as shown in the table above.
 
 
 
 
Max Connected  
     Required Power 
 
Minimum
Kenyon Part #    Model # 
       Load 
 
       Supply Input 
 
Wire Size
B80101  
  IND2BLG 
3700 Watts 
 
240VAC/16A/50/60Hz   
#12 AWG
B80105  
  IND2BLG 
3700 Watts 
 
240VAC/16A/50/60Hz   
#12 AWG
B80201  
  IND2BLG 
3700 Watts 
 
240VAC/16A/50/60Hz   
#12 AWG
B80205  
  IND2BLG 
3700 Watts 
 
240VAC/16A/50/60Hz   
#12 AWG
 
 
 
Warning:  If the electric power supply does not meet the product 
specifications, consult with a licensed electrician before proceeding 
with installation.
STEP #3
Countertop Preparation
Please read this section prior to making cutout for cooktop.
It is important to plan ahead for installation of the cooktop, keeping the following dimensions in 
mind (please refer to Figure A).
5
Ensure you have the correct model for your countertop.  Landscape models are designed for use 
in standard 24” depth countertops.  Portrait models are designed for use in islands and 
applications with non-standard depth countertops.  Generally 25 1/2” minimum countertop depth 
is needed to install portrait models.