Installation Specifications
Install a Support Platform in the 
Cabinet
Provide a platform (100 lb. load capacity) within the cabinet 
upon which the warming drawer will be supported. The 
platform must be installed level and straight. The top edge 
of the platform must be flush with the cutout at the front of 
the cabinet. There are no provisions to level the warming 
drawer after it has been installed. 3/4” (19 mm) thick 
plywood is recommended.
NOtE: 
If the drawer is not installed in a level fashion, the 
drawer may slide open on its own or may not seal 
tightly, allowing heat to escape and resulting in poor 
warming drawer performance.
Support
platform
Chassis
face
The warming drawer is supplied with a power cord 
terminated by a three-prong plug. Plug it directly into a 
dedicated, grounded, three prong, electrical outlet. Do 
not use an extension cord.
The correct voltage, frequency and amperage must be 
supplied to the electrical outlet from a grounded, single 
phase circuit that is protected by a properly sized circuit 
breaker or time-delay fuse.
The required voltage, frequency and amperage ratings 
are listed on the appliance data plate. The data plate 
is located inside the chassis drawer opening on the left 
side. Remove the drawer to expose it.
If the power supply requirements shown above do not 
agree with those listed on the product data plate, use 
the requirements on the product data plate. 
It is the owner’s responsibility to ensure that the 
electrical outlet is installed by a qualified electrician. 
The electrical installation must comply with the latest 
revision of the National Electric Code ANSI/NFPA 70 
and local codes and ordinances.
If the electrical service provided does not meet the 
product specification, or does not conform to the NEC 
or local standards, do not proceed with the installation. 
Call a licensed electrician to correct the electrical 
service before proceeding.
Be certain to locate the electrical outlet in an 
accessible location, so that the warming drawer may 
be easily unplugged in the event that service becomes 
necessary.
Electrical Power Supply 
Requirements
Nominal Electrical Supply Requirements
120 Vac, 60 Hz, 15 Amp. dedicated circuit
The warming drawer is supplied with a 40” (1016 mm) 
power cord with a three prong grounded plug.
total Connected Load 
0.5 kW (4 Amp.)
Three-Prong Plug
Three-Prong  
Grounded Outlet