Thermador PH36HS Installation Instruction

Page of 48
English 7
Duct covers, sold separately, are available to cover the 
space between the top of the hood and ceiling. (See 
page 3.)
12. Before hanging hood, install transition per Figure 7. 
Fasten transition with two (2) screws (#8 x 3/8 sheet 
metal, supplied) and tape per all applicable codes.
Note:
Screws must not hinder damper operation.
13. Rest the hood on the screws in the wood bracket. Use 
the keyholes labeled "I" in Figure 9. Make sure the 
wood bracket fits into the recess on the back of the 
hood.
14. Remove knockouts.
15. Tighten the screws in keyholes. Check hood levelness 
and adjust if necessary.
16. From inside the hood, drive screws (#8 x 5/8”) through 
holes in hood into wooden bracket. See holes labeled 
“J” in Figure 9.
17. Connect additional ducting.
Installation Note:
If wall studs are within 8" of the center line, cut stud at an 
angle to avoid any interference.
 Figure 8: Transition Centerline for Vertical Discharge
Transition
Centerline
Wall
5-13/16”
10-1/4”
18”
 Figure 9: Location of Screw Keyholes
I
I
J