Prestige PLBQ36300 Installation Instruction

Page of 14
 
 
 
 
3  
 
- Handling Precautions - 
•  Remove all rings, watches, belt buckles, jewelry and any clothing with metal buttons or 
snaps to prevent damage to hood. 
 
•  DO NOT REMOVE HOOD FROM ITS ORIGINAL CARTON UNTIL YOU ARE READY 
TO INSTALL IT. 
 
•  When you are ready to begin the installation process, remove the hood from its carton 
and place it on a clean soft blanket. 
 
•  Inspect the hood carefully for any damage or imperfections before you begin to install 
the hood. If any damage or imperfections exist, re-carton the hood and call your dealer 
IMMEDIATELY, do not install a damaged hood. 
 
•  It is highly recommended that rubber gloves be used to prevent scratches on the hood 
and to provide you with a firm grip. 
 
• 
When removing the hood from the carton locate the filters. The filters are not pre-
installed in the hood. The filters are in a box marked filters, inside the hood 
carton. 
 
•  PL model hoods can be ducted to the top or the rear. Check product guide for additional 
transitions, wall caps and roof caps. 
 
•  Duct size for 600CFM blowers is 6" round and an optional transition model TRC8/6 
should be used to increase the duct size to 8" round for optimal performance. 
 
•  PL3624, PL4224 and PL4824 require the use of transition model TR6x15/10 (NOT 
INCLUDED) when using a 1200CFM blower. 
 
•  All Prestige® ventilation hoods have a variable speed blower switch as well as a light 
dimmer switch. See Blower Installation instructions for further information on your 
installation application. 
 
•  PC model hoods can be ducted to the rear with the use of a 90º elbow. (NOT 
SUPPLIED) Check product guide for additional transitions, wall caps and roof caps. 
 
•  PC3024 hoods CANNOT accept the IBPC1200 internal blower. 
PC3624 & PC4224 
hood's duct size is 10" round when using the IBPC1200 internal blower. 
 
• 
All PC and PL hoods can be converted for ductless applications. See product 
guide for optional ductless conversion kits.