To determine if the base plate is high enough:
a.  Determine the location of the range center line and front 
panel when the range is in its final position based on 
the Product Dimensions on page 4 and the actual 
cabinet/cutout dimensions used for the installation.
b.  Determine and mark the required position of the anti-tip 
bracket, based on the diagram below. Push the bracket 
up against the wall in the mounting location.
c.  Using a pencil, make a dot next to the notches on both 
sides of the bracket. Determine if the base plate is as 
high at the notches by drilling test holes into the wall at 
both dots with a 1/16” drill bit. Drill just deep enough to 
see if the bit contacts the base plate. If the bit contacts 
the base plate the location will support wall installation 
of the anti-tip bracket. If you do not contact the base 
plate, or you contact metal stud mounting materials, the 
wall mounting method may not be used and the floor 
mounting method must be suitable, or the wall must be 
modified so that the base plate is above the notches.
4.  To install the bracket, place it against the wall in the mounting 
location shown below. Using a drill with 1/8” diameter drill bit, 
drill four (4) 1 5/8” deep pilot holes perpendicular to the screw 
seating surfaces shown. Attach the bracket to the wall as 
shown with the four (4) included #12 x 1 3/4 screws.
Installation Instructions
Drywall
Notch
Wall
Anti-tip 
bracket
Base 
plate
Top View - Location of Wall Mounted Anti-Tip Bracket
CL
CL
Range 
center line
#12 x 1 3/4” screw, 
4 places
Range front
panel
Bracket 
center line
Back wall
11 1/2” 
(29.2 cm)
25 1/4” 
(64.1 cm) 
to 
26 1/4 
(66.7 cm)
Cabinet  
face below 
countertop
Top hole, indicates
bracket center line
Top View - Location of Floor Mounted Anti-Tip Bracket
CL
#8 x 1”,  #8 x 1 1/4” 
or #12 x 1 3/4 screw, 
4 places (see text)
Range front
panel
Range 
center line
2 3/16” 
(5.6 cm)
10 1/2”
(26.3 cm)
21 3/8”
(54.3 cm)
Anchor, 4 places: 
use for concrete  
floor only
Front 
hole
Cabinet  
face below 
countertop
Anti-tip bracket 
front hole locations