13
Installation Instructions
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Fasten clamp 
tightly on pipe
3-Wire Conduit-Junction Box 
Connection with External Ground
Separate No. 10 (minimum)
copper grounding wire
Wire nut 
4 places
Conduit to  
appliance
Conduit to  
appliance
Wire nut 
3 places
Junction box
Junction box
3-Wire Conduit-Junction Box Connection
Connection to house 
power supply
Connection to house 
power supply