3)
Always use pipe-joint compound made for use with NATURAL
GAS and L.P. GAS between pressure regulator D  and NPT
adaptor  C  and between pressure regulator D  and pipe E. If a
flexible metal conductor is used, make sure that the tubing is not
kinked.
 
Use only pipes (E) conforming to standard regulations in force,
inserting gasket (supplied) between fitting adaptor C.
Always apply a suitable sealing substance (such as Teflon tape)
between pressure regulator D  and adaptor C  and between
pressure regulator and pipe E.
WARNING:  The tightening torque of adaptor (C ) must not be greater than 36 ozf - 10 Nm.
4)
The supply line must be fitted with an approved shut-off valve.
This valve should be located in the same room as the cooktop
and should be in a location where it can be easily opened and
closed.
Do not block access to the shut-off valve. The valve is necessary
for turning the gas to the appliance on or off.