Sirius SU900X Design Guide

Page of 1
6” Round Straight 
 
3- 1/4” x 10” 
 Straight 
6” 90 deg Elbow 
6” 45 deg Elbow 
3- 1/4” x 10” 
 90 deg Elbow 
3- 1/4” x 10” 
 45 deg Elbow 
3- 1/4” x 10” 
 90 deg Flat Elbow 
6” round to 3- 1/4” x 
10” transition 
3- 1/4” x 10” to 6” 
round transition 
6” round to 3- 1/4” x 
10” 90 deg transition 
3- 1/4” x 10” to 6” 
round transition elbow 
6” round wall cap  
damper 
3 1/4”x10” wall 
cap damper 
Round roof cap 
Round roof vent 
Duct Components  
    EL*   Q*   TEL* 
EL* = Effective Length: 
By assigning a penalty value to a particu-
lar fitting it is possible to arrive at a very 
good approximation of the effective length 
of the ducting run. 
Q* = Quantity of that component used 
TEL* = Total Effective Length 
Multiply the EL of each component by the 
quantity and total the column - this should 
not exceed 100 ft  
Your notes: 
Legend: 
Total of all TEL’s 
Ductwork Planning Guide 
General Information: 
The ductwork transports air born pollutants, moisture and very importantly heat out of the building. 
In addition to good ductwork planning and installation, it is vitally important that your fat filter is washed on a 
regular basis.  
The length of ductwork and the number of elbows should be kept to a minimum in order not to degrade the effi-
ciency of your range hood. 
Use duct tape to seal all joints and do not use flexible ducting as this not only creates air turbulence but also pro-
vides pockets for moisture and fat residue to condense - this poses a serious fire and health hazard .  Flexible 
ducting effectively double all of the EL’s below. 
Do not under any circumstances use plastic dryer ducting or 4” vent caps 
   1 
  15 
  9 
  15 
  9 
  20 
   1 
   5 
   5 
  15  
  30 
  30 
  26 
  24 
Worksheet for calculating the Effective Duct Length 
Ductwork Rough Drawing: 
With compliments of Sirius Range Hoods Ltd - www.siriushoods.com  Tel: 866 
528 4987