Fujitsu FS PRIMEPOWER 2500 SO8 BASE CABINET 128CPU D:GPK25-GA72 User Manual

Product codes
D:GPK25-GA72
Page of 4
Data Sheet 
⏐ IssueMarch 2005⏐ PRIMEPOWER 2500 
Page 4 / 4 
Environmental Data PRIMEPOWER 2500 
 
System cabinet 
Up to 64-way 
Exp. of base 
cabinet (1x) 
Up to 128-way 
I/O cabinet (4x) 
for each 8 
PCI/disk boxes 
PCI/disk box 
(max.32x) 4HE 
DPF cabinet 
(2x)
 
1 in each case for 
system and exp. 
cabinet 
Width 
1,066 mm 
1,066 mm 
644 mm 
(plus 189 mm 
connections for 1 
or 2 I/O cabinets) 
440 mm 
383 mm *3) 
 683 mm *4) 
Depth 
1,144 mm 
1,788 mm *1) 
1,036 mm 
670 mm 
726 mm *3) 
426 mm *4) 
Height 
1,800 mm 
174 mm 
1,800 mm 
Maintenance area 
Front 
Rear 
Left  
Right 
 
800 mm 
800 mm 
100 mm 
100 mm 
 
800 mm 
1,200 mm 
100 mm 
 
800 mm 
900 mm 
-- 
-- 
 
-- 
-- 
-- 
-- 
 
800 mm 
800 mm 
800 mm 
-- 
Weight 
900 kg 
650 kg 
230 kg' 
w/o PCI/Disk box 
40kg
 
300 kg *3) 
600 kg *4)
 
Rated voltage 
200-240 VAC ±10%  
Power supply  
4x standard  
2x expansion  
IEC309/32A  *2) 
6x standard  
IEC309/32A  *2) 
4x  
IEC309/16A  *2) 
2x  
IEC320-C14 (10A) 
See sys. & exp. 
cabinet 
Frequency 
50/60 Hz -4 to +2 % 
Power draw, max. 
22.5 KVA 
Sys. cab. 8SB 
42.5 KVA 
incl. sys. cabinet 
16SB 
-- 0.640 
KVA 
See sys. & exp. 
cabinet 
Power consumption, 
max. 
21 KVA 
Sys. cab. (8SB) 
40 KVA 
incl. sys. cabinet 
(16SB) 
-- 0.620 
KVA 
See sys. & exp. 
cabinet 
Heat generation, max. 
75,600 kJ/h 
Sys. cab. (8SB) 
144,000 kJ/h 
incl. sys. cabinet 
(16SB) 
-- 2,234 
kJ/h 
See sys. & exp. 
cabinet
 
Under-floor air 
conditioning 
--- 
necessary --- 
--- 
--- 
Operating Temperature / 
Operating height 
from 5 to 32º C / 0 - 1500 m 
from 5 to 30º C / 1500 - 2000m 
from 5 to 29º C / 2000 - 2500m 
from 5 to 27º C / 2500 - 3000m 
Relative humidity 
20% - 80%, non-condensing 
Safety 
IEC60950 ; C22.2 No.60950 ; ICES003 (CSA108.8) ; UL60950 
EMC 
EN55022 / CISPR22 Class A ; EN61000-3-2 / EN61000-3-3 
Electrical 
standards: 
Immunity 
EN55024 / CISPR24 
operation 
EN60721-3-3 , 3K2 or 3M2 or 3C2 or 3S2  
warehousing 
EN60721-3-1 , 1K2 or 1M3 or 1C2 or 1S2 
Mechanical 
standards: 
transport 
EN60721-3-2 , 2K2 or 2M2 or 2C2 or 2S1 
Ecology 
 
ECO ; FSC 03230 
*1) Including system cabinet 
*2) Installation with 32A or 16A safety cut-off type: D  
*3) In conjunction with stand alone system cabinet setup, without expansion cabinet. 
*4) Only in conjunction with system cabinet setup together with expansion cabinet 
DPF = Dual Power Feed Option 
 
All rights, including rights created by patent grant or registration of a utility model or design as well 
as rights of technical modifications are reserved. Delivery subject to availability. Designations may 
be trademarks, the use of which by third parties for their own purposes may violate the rights of the 
trademark owners. 
 
Copyright 
© Fujitsu Siemens Computers, 03/2005 
  Published by  
 
Fujitsu Siemens Computers 
http://www.fujitsu-siemens.com/ 
Company stamp