Dacor EHR4818SCH Design Guide
![Dacor](https://files.manualsbrain.com/attachments/4954f8bcef7a378c828bc6da55066afb497924da/common/fit/150/50/e69c4b5dc86781598887fa681edba83164cac22f17b4ad96213e63248859/brand_logo.png)
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
7.13
EH, EHR & MH Wall Mount
Range Hoods
30”, 36”, 42”, 48”, 54” Wide
Hoods
3/3
Revised
04/28/08
Front of
hood
Dual exhaust models*
Standard 8” duct connection
CL
Electrical access holes
7/8” Dia. (5.1 cm)
1 ½” (3.8 cm)
6 1/8”
(15.6 cm)
CL
CL
Single exhaust models**
Standard 8” duct connection
3” (7.6 cm)
4” (10.2 cm)
9 7/8”
(25.1 cm)
19 ¾”
(50.2 cm)
Back Dimensions
Models EH48, EHR48, MH48,
EH54, EHR54
All other models
3” (7.6 cm)
¾” (1.9 cm)
Electrical access holes
7/8” Dia. (5.1 cm)
CL
Bottom of
hood
Dual exhaust models*
Standard 8” duct connection
Single exhaust models**
Standard 8” duct connection
9 7/8”
(25.1 cm)
19 ¾”
(50.2 cm)
4” (10.2 cm)
D***
*
NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.
All tolerances: +1/16”, -0, (+1.6mm, -0)
unless otherwise stated
**
Top Dimensions
Rear Exhaust Placement
Hood Width
D
30”
9” (22.9 cm)
36”
8” (20.3 cm)
42”
17” (43.2 cm)
48” & 54”
14 7/16” (137.2 cm)