All Hoods Must Be Installed By A Qualified Installer
INSTALLATION INSTRUCTIONS 
WALL MOUNT RANGE HOOD WITH 
M600 OR M1200 BLOWER
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) 
in  accordance  with  all  applicable  codes  and  standards,  including  fire-
rated construction. Switch power off at service panel and lock the service 
disconnecting means to prevent power from being switched on accidentally 
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring 
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases 
through  the  flue  (chimney)  of  fuel  burning  equipment  to  prevent  back 
drafting.  Follow  the  heating  equipment  manufacturer’s  guideline  and 
safety standards such as those published by the National Fire Protection 
Association (NFPA), and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E.  ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to 
a maximum of 15 CFM per 100 square feet of occupiable space, unless a 
back drafting test is performed or make-up air is provided. Consult a local 
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL 
DUCTWORK