Crossover DAWF0GM Owner's Manual

Page of 38
112999-1
www.Laundrylux.com
3
Introduction __________________________
The Phase 5 Coin Computer System is a fully programmable,
highly sophisticated dryer control system.  The manufacturer
has designed the Phase 5 coin microprocessor controller
(computer) to be the most versatile and reliable coin-operated
control system available.
To eliminate as many moving p arts as possible, all Phase 5
coin microprocessor controller (computer) programming is
done through the membrane switch on the front of the control
panel.  The program switch that puts microprocessor controller
(computer) into the program mode is a single program switch.
This program switch eliminates the possibility of switch failure
due to an accumulation of lint or moisture.
Phase 5 Coin Microprocessor Controller
(Computer) Features
AUTOMATIC PROGRAM REVIEW
In the program mode, the Phase 5 coin microprocessor
controller (computer) will show all settings by one touch of the
low temperature keypad selection.
PROGRAMMABLE
Changes in the programs are made at the temperature keypad
selection and actual programs are displayed for verification.
ADJUSTABLE TIME
Programmable from a minimum of 1 minute to a maximum of
99 minutes in 1 minute increments.
COIN ACCEPTOR DENOMINATIONS
Values of coin acceptors are programmable from a minimum
of 1 to a maximum value of 9999 for any U.S. or foreign coin
denomination.
AMOUNT TO START
Programmable from a minimum value of 1 to a maximum value
of 9999 in increments of one.
ACCUMULATIVE TIME
This program yields a specific value of time for any coin entry
made after the “Amount To Start” has been inserted.
Time For Amount To Start
This program retains the time the owner wishes to vend.  The
feature allows any additional purchase that is made to be
calculated to the second.   There is no calculation necessary
by the owner .   The Phase 5 coin microprocessor controller
(computer) calculates the vended time.
ACCUMULATIVE COIN
This program selection requires that a specific value of coin(s)
be inserted for additional time, programmable for any minimum
amount.
COIN COUNT
The number of coins inserted, including a sep arate display
program for optional dual coin acceptors, can be viewed
through the Phase 5 computer ’s L.E.D. display.
BAD COIN LOCKOUT
Each coin is monitored.  Should someone t amper with the
coin acceptor or attempt to insert a foreign object, the
microprocessor controller (computer) will “LOCKOUT” and will
not accept any entries until the reset time has elap sed
(approximately 15-seconds).  Once the reset time has expired,
the microprocessor controller (computer) will automatically
reset itself for the next coin entry.
TEMPERATURE CONVERSION
When the temperature conversion status is changed (i.e. from
°F to °C), the Phase 5 coin microprocessor controller
(computer) will automatically convert all temperature related
programs/parameters from Fahrenheit to Celsius and vice
versa.  The Phase 5 coin microprocessor controller (computer)
will perform this conversion within 1° F (2° C).  The programs
affected are:
1. Temperature Display Mode
2. Temperature Selections
3. Cool Down Temperatures
DRYING TEMPERATURES
Any of the three temperature selections (HI/LO/PP) are
programmable from a minimum of 100° F to a maximum of
190° F in ten-degree increments or from a minimum of 38° C
to a maximum of 88° C in five-degree incrementt.   Actual
temperature programs are displayed at time of programming
for verification. Do not program temperature above 150° F (65° C)  
COOL DOWN TIME
All three temperature selections are programmable from a
minimum of 0 minutes to a maximum of 9 minutes in 1 minute
increments.
COOL DOWN TEMPERATURES
In the automatic or free dry modes, the cool down cycle
termination is programmable from a minimum of 70° F to a
maximum of 190° F in ten-degree increment s or from a
minimum of 21° C to a maximum of 88° C in five-degree
increments. Do not program temperature above 150° F (65° C)  
AUTOMATIC MODE (Patent No. 4,827,627)
This program selection uses a patented Auto-Dry cycle.  The
microprocessor controller (computer) will calculate the percent
of the dryness and read “donE” when complete.  The Phase 5
coin microprocessor controller (computer) can be programmed
to have a maximum time for the “Auto Mode.”  The Automatic
Cycle (mode) can be used in either the “Free Dry” Mode or
the “Coin” Mode.