Gaggenau AL400721 Brochure
98
Vario cooktops
V G 414 110F
Stainless steel
Width 38 cm
Liquid gas 28 – 37 mbar
Wok burner with 5 KW
Width 38 cm
Liquid gas 28 – 37 mbar
Wok burner with 5 KW
V G 414 210
Stainless steel
Width 38 cm
Natural gas 20 mbar
Wok burner with 6 KW
Width 38 cm
Natural gas 20 mbar
Wok burner with 6 KW
Installation accessories
V A 420 010
V A 420 010
Connection strip for combination with
other Vario appliances of the 400
series for surface installation
other Vario appliances of the 400
series for surface installation
V A 420 011
Connection strip for combination with
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
V A 420 000
Connection strip for combination with
other Vario appliances of the 400
series for flush installation
other Vario appliances of the 400
series for flush installation
V A 420 001
Connection strip for combination with
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
V A 440 010
Stainless steel appliance cover with
mounting strip
mounting strip
V A 450 400
Stainless steel adjustment strip 38 cm
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
S V 401 090
Spindle extensions up to 140 mm
S V 401 205
Spindle extensions up to 300 mm
Special accessories
W P 400 001
W P 400 001
Wok pan made of multiple-layer
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
Vario gas wok 400 series
V G 414
– Three-ring burner up to 6 kW
– Automatic fast ignition, electronic
flame monitoring
– Solid stainless steel control knob
– Precision crafting of 3 mm stainless
steel
– For surface installation with a
visible edge or for flush installation
– Can be combined perfectly with
other Vario appliances of the 400
series
series
Cooking zones
VG 414 110F
1 three-ring wok burner
(300 W – 5,000 W), suitable for pots up
to max. ø 32 cm.
1 three-ring wok burner
(300 W – 5,000 W), suitable for pots up
to max. ø 32 cm.
VG 414 210
1 three-ring wok burner
(300 W – 6,000 W), suitable for pots up
to max. ø 32 cm.
1 three-ring wok burner
(300 W – 6,000 W), suitable for pots up
to max. ø 32 cm.
Handling
Control knobs with cooking zone and
output level markings.
One-handed operation.
Gas valve with fine control.
output level markings.
One-handed operation.
Gas valve with fine control.
Features
Cast pan support with flat, continuous
pot surface.
Brass burner rings.
pot surface.
Brass burner rings.
Safety
Electronic flame monitoring with
automatic re-ignition.
Automatic fast ignition.
Safety shut-off.
automatic re-ignition.
Automatic fast ignition.
Safety shut-off.
Planning notes
Depending on the type of installation
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manufac-
turer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manufac-
turer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
Please read additional planning notes
on page 116–123 .
on page 116–123 .
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Control knobs to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Special nozzles can be ordered as
spare parts.
Plan for an electrical connection (the
appliance is not operable without
power supply).
Air intake from above.
No intermediate shelf required.
Rear panel and wall trims must be heat-
resistant and consist of a non-
flammable material.
A minimum lateral clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
If operated next to the downdraft
ventilation VL 414, the air baffle AA 414
is recommended to ensure maximum
performance of the cooktop.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 16 kg.
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Control knobs to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Special nozzles can be ordered as
spare parts.
Plan for an electrical connection (the
appliance is not operable without
power supply).
Air intake from above.
No intermediate shelf required.
Rear panel and wall trims must be heat-
resistant and consist of a non-
flammable material.
A minimum lateral clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
If operated next to the downdraft
ventilation VL 414, the air baffle AA 414
is recommended to ensure maximum
performance of the cooktop.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 16 kg.
Connection
Total connected load gas 5.0/6.0 kW .
Total connected load electric
15.0/15.0 W .
Connecting cable 1.4 m with plug.
Total connected load electric
15.0/15.0 W .
Connecting cable 1.4 m with plug.