Gaggenau AL400721 Brochure

Page of 356
110
Vario cooktops
    
   V   L 414 110
 
   Stainless  steel
  Ventilation  element
  Air extraction/recirculation with remote 
fan unit AR 400/401/403/413
  Without motor and control knob
          Necessary  installation  accessories
    A   A 490 110
 
  Vario control knob ventilation 400 
series
 Stainless  steel
    For operation of one remote fan unit 
AR 400/401/403/413
  In combination with up to four 
ventilation elements VL 414 connected 
to one remote fan unit
  Solid stainless steel control knob
  Can be combined perfectly with other 
Vario appliances of the 400 series
Installation accessories
     A   D 724 040
 
  Connection piece for cylindrical duct 
DN 125
    A   D 724 041
 
  Connection piece for cylindrical duct 
DN 125
   Necessary for installation to left or 
right side of VL 414.
     A   D 854 046
 
  Flat duct system with conducting fins
 Connection piece VL 414 for DN 150 
flat  rectangular    
     A   S 070 000
 
  Connection piece for extension in the 
case of installation next to VK or VF
      V   A 420 010
 
  Connection strip for combination with 
other Vario appliances of the 400 
series for surface installation
      V   A 420 011
 
  Connection strip for combination with 
other Vario appliances of the 400 
series for surface installation with 
appliance cover/adjustment strip
      V   A 420 000
 
  Connection strip for combination with 
other Vario appliances of the 400 
series for flush installation
      V   A 420 001
 
  Connection strip for combination with 
other Vario appliances of the 400 
series for flush installation with 
appliance cover/adjustment strip
      V   A 450 110
 
  Stainless steel adjustment strip 11 cm
   Required accessory for combination of 
several Vario appliances of the 400 
series with at least one appliance cover 
to compensate the appliance depth.
       Special  accessories
    A   A 414 010
 
  Air baffle for combination with gas 
cooktops
  Installation accessories for the air 
recirculation ducts you will find at the 
pages     236–239 .
          Vario  downdraft  ventilation  400  series
  V   L 414 
 
–    Highly efficient ventilation system at 
the cooktop
 
–   Up to 4 ventilation elements can be 
connected to one remote fan unit, 
operated using one control knob 
AA 490
 
–   Flexible power distribution, precise 
extraction of cooking vapours only 
at the open ventilation elements
 
–   Precision crafting of 3 mm stainless 
steel
 
–   For surface installation with a 
visible edge or for flush installation
 
–   Can be combined perfectly with 
other Vario appliances of the 400 
series
 
–   Compact ducting in connection 
with flat rectangular pipes AD 8..
 
–   Minimal planning and easy 
installation for air recirculation
     Output
  Maximum air output in combination 
with remote fan units s. table remote 
fan units on page 252/253.
  Sound power level depends on the 
built-in situation.
    Features
  Manual opening of the ventilation 
element.
  Closing element made of stainless 
steel, dishwasher-safe.
  Metal grease filter with grease drip 
tray, dishwasher-safe.
  Sensor-controlled operation of the 
extractor fan if at least one ventilation 
element VL 414 is open.
  No duct connection piece included.
    Planning  notes
  Depending on the type of installation 
(surface-mounted or flush-mounted, 
with or without an appliance cover), the 
specific location of the cut-out and the 
knob positions may vary.
  If installing with the appliance cover 
VA 440 or adjustement strip VA 450 
take into account the additional space 
required for the depth.
  If combining several appliances with at 
least one appliance cover, the 
adjustment strip VA 450 is required to 
compensate for the depth of the 
appliance without the appliance cover.
  If combining several Vario appliances 
of the 400 series, a connection strip 
VA 420 must be placed between the 
appliances. Depending on the type of 
installation, the corresponding 
connection strip must be provided.
  In the cut-out, the installation system 
requires the side edge to be at least 
10 mm for surface installation and at 
least 13 mm for flush installation. 
Ensure a continuous cut surface of 
90°.
  The bearing capacity and stability, in 
the case of thin worktops in particular, 
must be supported using suitable 
substructures. Take into account the 
appliance weight and additional loads.
  Additional instructions for flush installa-
tion:
  Installation is possible in worktops 
made of stone, synthetics or solid 
wood. Heat resistance and watertight 
sealing of the cut edges must be 
observed. Concerning other materials 
please consult the worktop manu-
facturer.
  The groove must be continuous and 
right, so that uniform placing of the 
appliance on the gasket is ensured. 
Do not use discontinuous lining.
  The joint width may vary due to size 
tolerances of the combinations and of 
the worktop cut-out.
Please read additional planning notes 
on  page     116–123 .
  If installing several appliances in 
individual cut-outs allow for a division 
bar of minimum 50 mm between the 
individual cut-outs.
  Air extraction operation in combination 
with remote fan units AR 400/401/403 
or recirculation mode with AR 413.
  Please refer to page 228–233 for 
recommended configurations of 
downdraft ventilations and remote fan 
units and the needed ducting 
elements.
  Maximum cooktop width between two 
VL: 60 cm.
  If operated next to gas appliances, the 
air baffle AA 414 010 is recommended 
to ensure maximum performance of the 
cooktop.
  If installed next to gas appliances, flat 
ducts must not be used for the piping 
up to the fan unit.
  If installed next to VP 414, the flat duct 
must not be positioned underneath the 
VP 414.
  For maximum duct lengths use 
Gaggenau flat rectangular ducts AD 8… 
or Naber-System Compair flow. Other 
flat ducts are not permitted!
  Pipe connection pieces must be 
ordered separately as installation 
accessories. Connection NW 125 
round on the bottom with AD 724 040, 
on the sides with AD 724 040 and 
AD 724 041.
Connection NW 150 flat ducting on the 
side with AD 854 042.
  Connection of 2 VL with ducting
2x DN 125 cylindrical or 2x DN 150 
rectangular at remote fan AR 4.. .
For leading through the floor DN 150 
cylindrical with connection of 2 DN 125 
cylindrical use Y-joint AD 754 044.
  Direct connection of 3 or 4 VL 414 only 
on one AR 400 140, without 
air-collector or Y-joint.
  Please ensure when installing the 
exhaust air ducting that no sharp 
bends are caused and that the 
cross-section of the ducting is not 
constricted in any way.
  For downdraft configurations with 
maximum lengths of exhaust air ducts 
go to Rodun at www.gaggenau.com.
  Appliance can be snapped into the 
worktop from above. Additional fixing 
by clamps accessible from above, 
clamping range 30-50 mm.
  Appliance weight: approx. 3 kg.  
    Connection
  Connection cable 2.0 m between 
ventilation element VL 414 and control 
knob AA 490.