Gaggenau AL400721 Brochure

Page of 356
118
Vario cooktops
The drawings listed below show the cut-out dimensions for appliance combinations in the 400 series for a flush installation.
While taking into consideration the previous page and the drawings specified below, the installer can define the suitable cut-out 
dimensions. The combinations listed here are only sample combinations.
Depending on the installation situation (with or without cover/adjustment strip), the following connection strips must be provided: 
VA 420 000 for a flush installation without appliance cover/adjustment strip.
VA 420 001 for a flush installation with appliance cover/adjustment strip.
If installing with the VA 440 appliance cover or VA 450 adjustment strip, take into account the additional space required for the depth. 
Furthermore, you must ensure that there is an asymmetrical alignment in the cut-out depth.
Sample combinations without VL 414 ventilation element:
All measurements in mm.
Cut-out dimensions for appliance combinations in the 400 series. Flush installation.