Gaggenau AL400721 Brochure

Page of 356
Vario cooktops
125
    
   V   G 264 114F
 
   Stainless  steel  control  panel
  Width  60  cm
  Liquid  gas  28 – 37 mbar
     V   G 264 214
 
   Stainless  steel  control  panel
  Width  60  cm
  Natural  gas  20  mbar
     V   G 264 134F
 
   Aluminium  control  panel
  Width  60  cm
  Liquid  gas  28 – 37 mbar
     V   G 264 234
 
   Aluminium  control  panel
  Width  60  cm
  Natural  gas  20  mbar
          Installation  accessories
    S   H 260 000
 
  Hinge holder for fitting the appliance 
cover
      V   V 200 014
 
  Stainless steel connection strip for 
combination with further Vario 
cooktops
      V   V 200 034
 
  Aluminium connection strip for 
combination with further Vario 
cooktops
        Special  accessories
    V   D 201 014
 
  Brushed stainless steel appliance 
cover (order two covers)
      V   D 201 034
 
  Shot-blasted  aluminium  appliance 
cover (order two covers)
          Vario  gas  cooktop  200  series
  V   G 264 
 
–    Can be combined with the 
cooktops of the Vario 200 series to 
a harmonic unity
 
–   Generous control panel for comfort-
able and secure operation
 
–   Solid smooth-surface cast pan 
supports for easy and safe 
positioning of cookware
 
–   9.4 KW on 4 burners
     Cooking  zones
  2 high output burners (560 – 2,800 W), 
suitable for pots up to max. ø 22 cm.
  2 standard burners (380 – 1,900 W), 
suitable for pots up to max. ø 22 cm.
    Handling
  Control knobs with cooking zone and 
output level markings.
  One-handed  operation.
  Electric  ignition.
  Gas valve with fine control.
    Features
  Two-part cast pan support with 
continuous pot surface.
  Enamelled  burner  cover.
    Safety
  Thermoelectric  safety  pilot.
    Planning  notes
  Special nozzles can be ordered as 
spare parts.
  Air intake from above.
  No intermediate shelf required.
  Appliance can be snapped into the 
worktop from above.
  Securing rail on the rear and the front.
  A minimum lateral clearance of at least 
150 mm from adjacent heat-sensitive 
furniture or contact surfaces must be 
observed or thermal insulation fitted.
  With a total connected load of more 
than 12 kW local regulations 
concerning room ventilation, room size 
and combination of extraction or 
recirculation hoods must be observed. 
Minimum clearance between gas 
cooktop(s) with more than 12 kW and 
ventilation hood 70 cm.
  Special nozzles (order 2 of each):
Part No. 433603 Natural gas 20 mbar
Part No. 419831 Liquid gas 30 mbar
Part No. 419830 Liquid gas 50 mbar
    Connection
  Total connected load gas  9.4 kW .
  Total  connected  load  electric   1.0    W .
  Connecting cable 1.4 m with plug.