Ventilation appliances
A C 402 180
Stainless steel
Filter module
Air extraction/recirculation with remote
fan unit AR 400/401
Motorless
Filter module
Air extraction/recirculation with remote
fan unit AR 400/401
Motorless
Installation accessories
A D 704 044
A D 704 044
Air collector box DN 200 cylindrical
duct
2 x DN 150 cylindrical duct air intake.
1-2 x DN 200 cylindrical duct air outlet.
duct
2 x DN 150 cylindrical duct air intake.
1-2 x DN 200 cylindrical duct air outlet.
A D 854 044
Air collector box DN 150 flat duct
2 x DN 150 flat duct air intake.
1 x DN 200 flat duct air outlet.
2 x DN 150 flat duct air intake.
1 x DN 200 flat duct air outlet.
Special accessories
K F 273 198
K F 273 198
Activated charcoal air filter
Vario ceiling ventilation
A C 402
– Discreet integration into the
architecture of the kitchen
– Flexible by dimension, performance
and ventilation mode
– Room ventilation
– Modular ceiling ventilation which
can be configurated individually by
separate components such as filter
module, control modules and light
module
separate components such as filter
module, control modules and light
module
– Individual configuration of
unobstructed airflow of remote fan
unit from 950 – 2,800 m³/h
unit from 950 – 2,800 m³/h
– Highly efficient patented rim
extraction
– Planed and easy to clean underside
with covered filters
Output
Maximum air output in combination
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
Features
Rim extraction filter, dishwasher-safe.
Installation frame for thread rods (rods
not included).
Connection piece DN 150 cylindrical.
Installation frame for thread rods (rods
not included).
Connection piece DN 150 cylindrical.
Planning notes
The ceiling ventilation has to be
handled as a room ventilation when
distance to cooktop is larger than
120 cm since the direct capture of
vapours will be limited. The needed
airflow is given by an air exchange rate
of 10 to 12 times the room volume.
Please refer to page 198/199 for
recommended configurations of ceiling
ventilations and remote fan units and
the resulting dimensions.
Air extraction in combination with
remote fan unit AR 400/401. For
recirculation mode 1 activated carbon
filter KF 273 198 per filter module is
needed.
Max. 2 filter modules to be connected
to 1 AR 400 131 or AR 401 131/140.
Max. 4 filter modules to be connected
to 1 AR 400 140.
When installing remote fan unit AR 400
within the ceiling or furniture block it
must remain accessible through the
ceiling cutout or another maintenance
access.
To be installed in standard ceiling or
furniture cutout which will be covered
by module frames with 0.8 mm
thickness.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood’s power sup-
ply line needs a suitable safety switch.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
handled as a room ventilation when
distance to cooktop is larger than
120 cm since the direct capture of
vapours will be limited. The needed
airflow is given by an air exchange rate
of 10 to 12 times the room volume.
Please refer to page 198/199 for
recommended configurations of ceiling
ventilations and remote fan units and
the resulting dimensions.
Air extraction in combination with
remote fan unit AR 400/401. For
recirculation mode 1 activated carbon
filter KF 273 198 per filter module is
needed.
Max. 2 filter modules to be connected
to 1 AR 400 131 or AR 401 131/140.
Max. 4 filter modules to be connected
to 1 AR 400 140.
When installing remote fan unit AR 400
within the ceiling or furniture block it
must remain accessible through the
ceiling cutout or another maintenance
access.
To be installed in standard ceiling or
furniture cutout which will be covered
by module frames with 0.8 mm
thickness.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood’s power sup-
ply line needs a suitable safety switch.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
A C 482 180
Stainless steel
Control module with light
For controlling remote fan units
AR 400/401
Control module with light
For controlling remote fan units
AR 400/401
A C 462 180
Stainless steel
Control module without light
For controlling remote fan units
AR 400/401
Control module without light
For controlling remote fan units
AR 400/401
Special accessories
A A 090 100
A A 090 100
Circuit amplifier for connecting two
remote fan units
remote fan units
Vario ceiling ventilation
A C 482/A C 462
– Control module of ceiling
ventilation with light
– Individual configuration of
unobstructed airflow of remote fan
unit from 950 – 2,800 m³/h
unit from 950 – 2,800 m³/h
– Individual integration of light
elements into the configuration of
the ceiling ventilation
the ceiling ventilation
Output
Maximum air output in combination
with remote fan units s. table remote
fan units on page 252/253.
with remote fan units s. table remote
fan units on page 252/253.
Features
7-key infrared remote control, backup
keys for operation also on the control
module.
3 electronically controlled output
levels.
Intensive mode.
Run-on function.
Acoustic grease filter saturation
indicator.
Dimmable halogen Soft-Light 2 x 20 W
(only at AC 482).
keys for operation also on the control
module.
3 electronically controlled output
levels.
Intensive mode.
Run-on function.
Acoustic grease filter saturation
indicator.
Dimmable halogen Soft-Light 2 x 20 W
(only at AC 482).
Planning notes
Fixing at the filter module.
Max. 2 AR 400/401 to be controlled
with one control module.
One amplifier AA 090 100 is needed for
connecting two remote fan units.
Max. 2 additional light modules
connected to one control module with
light.
Fit one socket within the area of
control module, two sockets when
using amplifier AA 090 100.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Max. 2 AR 400/401 to be controlled
with one control module.
One amplifier AA 090 100 is needed for
connecting two remote fan units.
Max. 2 additional light modules
connected to one control module with
light.
Fit one socket within the area of
control module, two sockets when
using amplifier AA 090 100.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Connection
Total connected load max.
355 – 1,160 W.
Connecting cable 1.3 m with plug.
355 – 1,160 W.
Connecting cable 1.3 m with plug.