Ventilation appliances
    
   A   C 402 180
 
   Stainless  steel
  Filter  module
  Air extraction/recirculation with remote 
fan unit AR 400/401
  Motorless
          Installation  accessories
    A   D 704 044
 
  Air collector box DN 200 cylindrical 
duct
   2 x DN 150 cylindrical duct air intake.
  1-2 x DN 200 cylindrical duct air outlet.
     A   D 854 044
 
  Air collector box DN 150 flat duct
   2 x DN 150 flat duct air intake.
  1 x DN 200 flat duct air outlet.
       Special  accessories
    K   F 273 198
 
  Activated charcoal air filter
          Vario  ceiling  ventilation
  A   C 402 
 
–    Discreet  integration  into  the 
architecture of the kitchen
 
–   Flexible by dimension, performance 
and ventilation mode
 
–   Room  ventilation
 
–   Modular ceiling ventilation which 
can be configurated individually by 
separate components such as filter 
module, control modules and light 
module
 
–   Individual  configuration  of 
unobstructed airflow of remote fan 
unit  from  950 – 2,800 m³/h
 
–   Highly efficient patented rim 
extraction
 
–   Planed and easy to clean underside 
with covered filters
     Output
  Maximum air output in combination 
with remote fan units s. table remote 
fan units on page 252/253.
  Sound power level depends on the 
built-in situation.
    Features
  Rim extraction filter, dishwasher-safe.
  Installation frame for thread rods (rods 
not included).
  Connection piece DN 150 cylindrical.
    Planning  notes
  The ceiling ventilation has to be 
handled as a room ventilation when 
distance to cooktop is larger than 
120 cm since the direct capture of 
vapours will be limited. The needed 
airflow is given by an air exchange rate 
of 10 to 12 times the room volume.
  Please refer to page 198/199 for 
recommended configurations of ceiling 
ventilations and remote fan units and 
the resulting dimensions.
  Air extraction in combination with 
remote fan unit AR 400/401. For 
recirculation mode 1 activated carbon 
filter KF 273 198 per filter module is 
needed.
  Max. 2 filter modules to be connected 
to 1 AR 400 131 or AR 401 131/140. 
Max. 4 filter modules to be connected 
to 1 AR 400 140.
  When installing remote fan unit AR 400 
within the ceiling or furniture block it 
must remain accessible through the 
ceiling cutout or another maintenance 
access.
  To be installed in standard ceiling or 
furniture cutout which will be covered 
by module frames with 0.8 mm 
thickness.
  When installing a ventilation hood with 
air extraction mode and a chimney-
vented fireplace, the hood’s power sup-
ply line needs a suitable safety switch.
  For maximum duct lengths use 
Gaggenau flat rectangular ducts AD 8… 
or Naber-System Compair flow. Other 
flat ducts are not permitted!
  Please ensure when installing the 
exhaust air ducting that no sharp 
bends are caused and that the 
cross-section of the ducting is not 
constricted in any way.
  For downdraft configurations with 
maximum lengths of exhaust air ducts 
go to Rodun at www.gaggenau.com.
       
    
   A   C 482 180
 
   Stainless  steel
  Control module with light
  For controlling remote fan units 
AR 400/401
     A   C 462 180
 
   Stainless  steel
  Control module without light
  For controlling remote fan units 
AR 400/401
            Special  accessories
    A   A 090 100
 
  Circuit amplifier for connecting two 
remote fan units
          Vario  ceiling  ventilation
  A   C 482/A   C 462 
 
–    Control  module  of  ceiling 
ventilation with light
 
–   Individual  configuration  of 
unobstructed airflow of remote fan 
unit  from  950 – 2,800 m³/h
 
–   Individual integration of light 
elements into the configuration of 
the ceiling ventilation
     Output
  Maximum air output in combination 
with remote fan units s. table remote 
fan units on page 252/253.
    Features
  7-key infrared remote control, backup 
keys for operation also on the control 
module.
  3 electronically controlled output 
levels.
  Intensive  mode.
  Run-on  function.
  Acoustic grease filter saturation 
indicator.
  Dimmable halogen Soft-Light 2 x 20 W 
(only at AC 482).
    Planning  notes
    Fixing  at  the  filter  module.
  Max. 2 AR 400/401 to be controlled 
with one control module.
  One amplifier AA 090 100 is needed for 
connecting two remote fan units.
  Max. 2 additional light modules 
connected to one control module with 
light.
  Fit one socket within the area of 
control module, two sockets when 
using amplifier AA 090 100.
  When installing a ventilation hood with 
air extraction mode and a chimney-
vented fireplace, the hood's power 
supply line needs a suitable safety 
switch.
    Connection
  Total connected load max. 
355 – 1,160 W.
  Connecting cable 1.3 m with plug.