Gaggenau AL400721 Brochure

Page of 356
198
Ventilation appliances
Planning as a cooktop ventilation wall/island (W/I) up to max. 120 cm distance to 
the cooktop.
For larger distances planning as room ventilation (R) with air exchange rates 
10 to 12 times the room volume. 
The given airfl ow of the remote fan units will be reduced by the diff erent ducting 
types between fi lter modules and AR 400/401 as well as by the further ducting. 
For additional ducting chose the confi guration with higher airfl ow.
Bold print: favoured confi guration
Regular print: possible confi guration
Other: – Not possible due to performance or ducting reasons
Respect the positioning of the remote fan units and the run of the ducts.
Modules of ceiling ventilation:
F = Filter module (FL = in-line confi guration)
CL = Control module with light
CO = Control module without
L = Light module
Minimal construction 
height including 
installation frame
150 - 160
Structure within ceiling/
furniture element
Minimal construction height with fl exible aluminium ducting straight 
through the ceiling.
Remote fan unit separately placed.
Air collector box, if 
needed
(AD 704 044)
2–3 x DN 150 cylindrical duct-> 1-2x DN 200 cylindrical duct
Maximal width of 
cooktop
Cooktop ventilation, 
max. distance 120 cm:
W = Cooktop ventilation 
wall
I = Cooktop ventilation 
island
R = Room ventilation, 
distance > 120 cm
Ceiling cutout
a x b
(frame size)
mm
Remote fan unit inside installation
(unobstructed airfl ow fan unit 
alone)
Duct behind fan DN 200
Remote fan unit outside 
installation wall/roof
(unobstructed airfl ow fan unit 
alone)
Range of unbstructed airflow of remote fan units 950 - 1,400 m³/h 
No air collector box necessary
FL1-CL
FL1-CO
W: 80 cm
I: 60 cm, 
no VR, VP, VF
R: -
765 x 515
(800 x 540)
1x AR 400 131 (1,000 m³/h)
1x AR 400 140 (1,400 m³/h)
1x AR 401 131 (950 m³/h)
1x AR 401 140 (1,200 m³/h)
FL1-CL-L1
W: 80 cm
I: 60 cm, 
no VR, VP, VF
R: -
765 x 660
respect direction!
(800 x 680)
1x AR 400 131 (1,000 m³/h)
1x AR 400 140 (1,400 m³/h)
1x AR 401 131 (950 m³/h)
1x AR 401 140 (1,200 m³/h)
Range of unbstructed airflow of remote fan units 950 - 2,800 m³/h
FL2-CL-L1
W: 120 cm, 
VR, VP, VF centered
I: 90 cm, no VR, VP, VF
R:  -
1,565 x 515
(1,600 x 540)
1x AR 400 131 (1,000 m³/h)
1x AR 400 140 (1,400 m³/h)
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
1x AR 401 131 (950 m³/h)
1x AR 401 140 (1,200 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
F2-CL
F2-CO
W: -
I: 80 cm
R: 60 cm,
10x air exchange rate,
no VR, VP, VF 
915 x 765
respect direction!
(940 x 800)
1x AR 400 131 (1,000 m³/h)
1x AR 400 140 (1,400 m³/h)
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
1x AR 401 131 (950 m³/h)
1x AR 401 140 (1,200 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
F2-CL-L2
W: -
I: 80 cm
R:  60 cm,  
10x air exchange rate,
no VR, VP, VF  
1,200 x 765
(1220x 800
1x AR 400 131 (1,000 m³/h)
1x AR 400 140 (1,400 m³/h)
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
1x AR 401 131 (950 m³/h)
1x AR 401 140 (1,200 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
Range of unbstructed airflow of remote fan units 1,400 m³/h
2 AR: divide airflow of center modules with air collector
F3-CL-L1
W:  -
I: 120 cm, VR, VP, VF 
centered
R: 120 cm, 10x air 
exchange rate,
12x with VR, VP, VF 
1,455 x 765
(1,480 x 800)
1x AR 400 140 (1,400 m³/h)
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
Range of unbstructed airflow of remote fan units 1,400 - 2,800 m³/h
F4-CO
W:  -
I: 120 cm, VR, VP, VF 
centered
R: 120 cm, 10x air 
exchange rate
12x with VR, VP, VF
1,715 x 765
(1,740 x 800)
1x AR 400 140 (1,400 m³/h)¹
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
FL4-CL-L1
W:  -
I: 120 cm, VR, VP, VF 
centered
R: 120 cm, 10x air 
exchange rate,
12x with VR, VP, VF
2 cutouts 765 x 915
with 35 mm distance 
and support in the 
middle. Total cutout 
1,565 x 915 with division 
bar. (1,600 x 940)
1x AR 400 140 (1,400 m³/h)¹
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
F4-CL-L2
W:  -
I: 160 cm, VR, VP, VF 
centered
R: 160 cm, 10x air 
exchange rate,
12x with VR, VP, VF
1,995 x 765
(2,020 x 800)
1x AR 400 140 (1,400 m³/h)¹
2x AR 400 131 (2,000 m³/h)
2x AR 400 140 (2,800 m³/h)
2x AR 401 131 (1,900 m³/h)
2x AR 401 140 (2,400 m³/h)
¹ Do not use air collector boxes. Ducting with 4x DN 150 
directly to AR 400 140
Recommended configurations for ceiling ventilation.